BFT VISTA SL1 Instrucciones De Uso Y De Instalacion página 22

Ocultar thumbs Ver también para VISTA SL1:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45
14.2) LOGIC MENU (logic)
LOGIC
DEFAULT
OFF
TCA
OFF
antipanic
OFF
MASTER
OFF
bussola
OFF
iNT EXT
TEST PHOT
OFF
open
TEST PHOT
OFF
close
OFF
ram blow c. o p
OFF
fixed code
OFF
radio prog
21-22-23
"Alarm" output
21 = NO (voltage-free contact)
22 = COM (voltage-free contact)
23 = NC (voltage-free contact)
14.4) LOGIC MENU (RADIO)
(fig.B)
- Add Open Key (add open)
Associates the desired key with the "open" command.
Once memorized, it returns the number of the receiver in the memory
location (from 01 to 63).
- Add Open Key key (add key)
Associates the desired key with the "open key" command. Once
memorized, it returns the number of the receiver in the memory loca-
tion (from 01 to 63).
- Read (read)
Checks a key of a receiver and, if memorized, returns the number of
the receiver in the memory location (from 01 to 64) and number of
the key (T1-T2-T3 or T4).
- Eliminate list (erase 64)
WARNING! Erases all memorized remote controls from the receiver's
memory.
- Receiver code reading (cod RX)
Displays the code entered in the receiver.
- W LINK (uk)
ON =
Enables remote programming of cards via a previously memorized
W LINK remote control.
It remains enabled for 3 minutes from the time the W LINK remote
control is last pressed.
Refer to the W LINK remote control's manual for the mapping of the
relevant keys.
OFF =
W LINK programming disabled.
14.5) LANGUAGE MENU (LAnguage)
Used to set the programmer's language on the display.
There are 5 language options:
- ITALIAN (ITA)
- FRENCH (FRA)
- GERMAN (DEU)
- ENGLISH (ENG)
- SPANISH (ESP)
14.6) DEFAULT MENU (DEFAULT)
Restores the controller's default factory settings.
Following this reset, you will need to run the autoset function again.
22
- VISTA SL - Ver. 01
INSTALLATION MANUAL
Automatic Closing ON/OFF (TCA and Clear Time)
Panic Feature ON/OFF (Section 15.8)
Master/Slave door (Sect.15.10)
"ON" Door set as MASTER in connection for management of commands via central controllers.
"OFF" Door set as SLAVE in connection for management of commands via central controllers.
"ON" Revolving mode. Single/revolving door (Sect.15.11)
"OFF" Single door mode
Internal/External door (Sect.15.11)
"ON" Door set as EXTERNAL in "Revolving" mode.
"OFF" Door set as INTERNAL in "Revolving" mode.
Safety device testing during opening
"ON" Device testing ON during opening
"OFF" Device testing OFF during opening
Safety device testing during closing
"ON" Device testing ON during closing
"OFF" Device testing OFF during closing
Hammer ON/OFF during opening
ON:
Receiver is configured for operation in fixed-code mode.
OFF: Receiver is configured for operation in rolling-code mode.
ON:
Enables wireless memorizing of transmitters:
1- Press in sequence the hidden key (P1) and normal key (T1-T2-T3-T4) of a transmitter that has already been
memorized in standard mode via the radio menu. 2- Press within 10 sec. the hidden key (P1) and normal key
(T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmitters. This
mode does not require access to the control panel.
OFF: Disables wireless memorizing of transmitters.
menu.
(fig.B)
(fig.B)
DESCRIPTION
Transmitters are memorized only using the relevant Radio
14.7)AUTOSET MENU (autoset)
When this function is activated, the parameters relating to door movement
and obstacle detection are automatically set to their optimum values:
- Running speed during opening
- Running speed during closing
- Opening slow-down distance
- Closing slow-down distance
- Opening deceleration distance
- Closing deceleration distance
- Acceleration
- Deceleration
- Opening torque
- Closing torque
3 complete cycles are performed as the autoset function is run.
While autoset is running, the anti-crush function is not active.
The door must not be stopped or slowed down at any point during its
travel while autoset is running.
15) CENTRAL OPERATION:
15.1) DOOR OPERATION MODE
Mode 0) Standard operation door (fig.25)
Reaction to commands:
- Open key:
Opens at high speed, closes at low speed. Opens and activates an Open-key
operation, if activated while the door is open, it sets clear time to zero; reopens
if activated during closing.
With the door open, the clear-time countdown is
active. During closing, photocells stop movement instead of reversing.
Once they are cleared, closing is resumed following the TCA countdown.
During the Open-key operation, the radars are not active
- External radar:
Performs a high-speed cycle. Opens, with the door open, it triggers
the automatic closing time; if activated while the door is open, it sets
automatic closing time to zero. If clear time was active - activated by
an Open-key operation - with the door open, this time is converted
into automatic closing time. Following the automatic closing time, the
door closes. During closing, it causes the door to open again.
During closing, it carries out a reopening manoeuvre.
- Internal radar:
Opens, with the door open, it triggers the automatic closing time; if
activated while the door is open, it sets automatic closing time to zero.
If clear time was active - activated by an Open-key operation - with the
door open, this time is converted into automatic closing time.
Following the automatic closing time, the door closes. During clo-
sing, it causes the door to open again.
ENGLISH