Descargar Imprimir esta página

Stanley RL HW Manual De Instrucciones página 16

Ocultar thumbs Ver también para RL HW:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 56
extended time.
L
Reference Figure
each key.
Remote Control
The same functions / modes for each specific laser tool
are accessible through use with the keys available on
the remote.
The laser tool can be powered OFF with the remote
by pressing both
tool can only be powered ON with the power key on
the laser tool.
Accuracy Check and
Calibration
NOTE:
See Feature Set to reference which models offer specific
functions.
The laser tools are sealed and calibrated at the factory to
the accuracies specified.
It is recommended to perform a calibration check prior to its
first use and then periodically during future use.
Be sure to allow the laser tool adequate time to Auto-Level
(< 60 seconds) prior to a calibration check.
The laser tool should be checked regularly to ensure its
accuracies, especially for precise layouts.
Horizontal Check
Set the laser tool on a tripod 20 m away from a wall with
the "X1" side facing the wall (
Power ON the laser tool and allow the laser tool to Auto-
Level and be sure laser is rotating.
Go to the wall and mark a reference point "D
the laser line is on the wall. If available, using a detector
may help in locating the beam more easily.
Loosen the laser tool from the tripod and rotate the
laser tool 180° so that the "X2" side is now facing the
wall (
).
N
2
Go back to the wall and measure the distance between
the first reference point "D
16
for resulting slope direction for
at the same time. The laser
N
(See Figure
)
).
N
1
" where
1
" and the second reference
1
point "D
" (
N
).
3
2
There is no need to adjust calibration if the distance
between reference point "D
If the distance measured is ≥ 2,0 mm then a calibration
adjustment is necessary.
Perform the same steps for the "Y" axis as was done
for the "X" axis. Replace "X1" and "X2" with Y1" and
"Y2" (
) .
N
4
Horizontal Calibration
(For RL HW substitute
referenced below)
(For RL HW / RL HW+ substitute
is referenced below)
With laser tool powered OFF, press and hold
followed by
.
Release
and continue to hold
seconds.
Release
.
The LED/LCD will indicate laser tool is in Calibration
mode.
If necessary, adjust the "X" axis by pressing
until the laser beam is aligned with "D
halfway point between "D
check.
Press
again to set the "X" axis and / or proceed to
the "Y" axis adjust.
If necessary, adjust the "Y" axis by pressing
until the laser beam is aligned with "D
halfway point between "D
check.
77-496 / 77-429 / 77-439 / 77-497 / 77-427 / 77-441
" and "D
" is < 2,0 mm.
1
2
N
(See Figure
)
where ever
is
where ever
for ≥ 3
". "D
" is the
0
0
" and "D
" during "X" axis
1
2
". "D
" is the
0
0
" and "D
" during "Y" axis
1
2

Publicidad