Press
again to set the "X" axis and / or proceed to
exit Calibration Mode.
Axis settings are now saved, Calibration Mode is OFF,
and laser tool begins Auto-Levelling as done when
initially powered ON.
NOTE:
A press of
will slope the axis by 3,5 arc
seconds. Reference Figure
for each key.
If the laser tool can still not be calibrated after
following the Calibration procedure, please send the
laser tool into an Authorized Service Center for repair.
Vertical Check
(See Figure
(Only necessary on models with Vertical Auto-Levelling)
Set the laser tool on a stable surface in its vertical
position 1 m away from a wall that extends ≥ 2 m high
with the "Y1" side facing that wall (
Power ON the laser tool and allow the laser tool to Auto-
Level and be sure laser is rotating.
Mark reference points "A" (where laser line is on
floor 1 m away from wall), "B " (where laser beam
is at corner), and "D
1
the wall).
Rotate the laser tool 180° so that the "Y2" side is now
facing the wall (
).
P
2
Align the laser beam with reference points "A" and "B"
and then go back to the wall and measure the distance
between the reference point "D
There is no need to adjust calibration if the distance
between reference point "D
If the distance measured is ≥ 1,0 mm then a calibration
adjustment is necessary.
Vertical Calibration
(For RL HW+ substitute
referenced below)
With laser tool powered OFF, press and hold
77-496 / 77-429 / 77-439 / 77-497 / 77-427 / 77-441
L
for resulting slope direction
)
P
).
P
1
" (where laser beam is 2 m up
" and "D
" (
).
P
3
1
2
" and "D
" is < 1,0 mm.
1
2
(See Figure
)
P
where ever
followed by
Release
seconds.
Release
The LED/LCD will indicate laser tool is in Calibration
mode.
If necessary, adjust the vertical "X" axis by pressing
" is the halfway point between "D
"D
0
vertical axis check.
.
Press
Axis setting is now saved, Calibration Mode is OFF,
and laser tool begins Auto-Levelling as done when
initially powered ON.
NOTE:
A press of
seconds. Reference Figure
for each key.
If the laser tool can still not be calibrated after
following the Calibration procedure, please send the
laser tool into an Authorized Service Center for repair.
is
.
and continue to hold
.
until the laser beam is aligned with "D
" and "D
1
to set the vertical "X" axis.
will slope the axis by 3,5 arc
for resulting slope direction