Safety instructions for the wiring and instalation of this apparatus
The following safety instructions apply specifically to all EU member states. They should be
strictly adhered to in order to assure compliance with the Low Voltage Directive. Non-EU states
should also comply with the following unless superseded by local or National Standards.
1. Adequate earth connections should be made to all earthing points, internal and external, where
provided.
2. After installation or troubleshooting, all safety covers and safety grounds must be replaced. The
integrity of all earth terminals must be maintained at all times.
3. Mains supply cords should comply with the requirements of IEC227 or IEC245.
4. All wiring shall be suitable for use in an ambient temperature of greater than 75°C.
5. All cable glands used should be of such internal dimensions as to provide adequate cable
anchorage.
6. To ensure safe operation of this equipment, connection to the mains supply should only be made
through a circuit breaker which will disconnect all circuits carrying conductors during a fault situation.
The circuit breaker may also include a mechanically operated isolating switch. If not, then another
means of disconnecting the equipment from the supply must be provided and clearly marked as such.
Circuit breakers or switches must comply with a recognized standard such as IEC947. All wiring must
conform with any local standards.
7. Where equipment or covers are marked with the symbol to the right,
hazardous voltages are likely to be present beneath. These covers should only
be removed when power is removed from the equipment - and then only by
trained service personnel.
8. Where equipment or covers are marked with the symbol to the right, there is a
danger from hot surfaces beneath. These covers should only be removed by
trained service personnel when power is removed from the equipment. Certain
surfaces may remain hot to the touch.
9. Where equipment or covers are marked with the symbol to the right, refer to
the Operator Manual for instructions.
10. All graphical symbols used in this product are from one or more of the
following standards: EN61010-1, IEC417, and ISO3864.
IMPORTANT
OCX 8800
A-12