1- Timer
2- Reduce fan speed
3- Increase fan speed
4- Light
Before
carrying
maintenance activities, ensure that the
extractor is disconnected from the mains.
To carry out cleaning and maintenance,
follow the Safety Instructions.
Fire risk exists in case that cleaning does not
take place according to the instructions.
Filter cleaning
To withdraw the filters from their locations
release the anchoring points. Clean the filter,
either by putting it in the dishwasher (see
notes) or leaving it standing in hot water to
simplify the removal of grease or, if wished,
by means of special sprays (protecting the
non-metallic parts). Once clean, leave it to
dry.
Notes: cleaning in the dishwasher with
aggressive detergents may blacken the
surface of metallic parts, without this
affecting its gas retaining properties.
N.B. The filter must be cleaned at least once
a month depending on how often the
extractor is used. It must be remembered
that grease is deposited in the extractor
when cooking, whether it is switched on or
not.
Electrical characteristics:
REFER TO RATING PLATE
16
out
any
cleaning
Working time
1) Switch on the cooker hood and choose
the required aspiration speed.
2)
3) When time is up, motor and lamp will be
turned off.
or
Cleaning of the extractor body
The use of warm (40ºC approx.) soapy water
is recommended. A cloth moistened in this
water is used for cleaning the extractor,
paying
special
Afterwards, dry it using a lint-free cloth.
Note:
• Never use metallic scouring pads or
abrasive products that could damage
the surface.
• Do not use scrapers with metallic
surfaces such as knives, scissors etc.
Activated charcoal filter
• To install the charcoal filter, the motor
anchorage is made to coincide with the
anchor points of the activated charcoal
filter and turn it clockwise.
• The carbon filter lasts from three to six
months depending on the particular
conditions of use.
• The activated carbon filter can neither
be washed nor regenerated. Once it is
exhausted, it must be changed.
• To replace exhausted filters with new
ones, withdraw the old one in the
reverse order to that of installation.
minutes.
attention
to
the
grids.