Disassembly And Disposal; Maintenance; Technical Specifications - SICK WTV4F Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 76
8

DISASSEMBLY AND DISPOSAL

8
Disassembly and disposal
9

Maintenance

10

Technical specifications

Recommended sensing range for the best performance
Sensing range max.
Light spot diameter/distance
Supply voltage U
B
Ripple
Output current I
max.
14
LED indicator/fault pattern
Yellow LED lights up, no object
in the path of the beam
Object is in the path of the
beam, yellow LED does not
light up
No object in beam path, no
output signal
The sensor must be disposed of according to the applicable country-specific regula‐
tions. Efforts should be made during the disposal process to recycle the constituent
materials (particularly precious metals).
NOTE
Disposal of batteries, electric and electronic devices
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
WEEE:
This symbol on the product, its package or in this document,
indicates that a product is subject to these regulations.
SICK sensors are maintenance-free.
We recommend doing the following regularly:
Clean the external lens surfaces
Check the screw connections and plug-in connections
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
Cause
The sensing range distance is
too large
Distance between the sensor
and the object is too long or
sensing range is set too short
Test input (Test) is not con‐
nected properly
WTV4F
15 mm ... 30 mm
2 mm ... 50 mm (Typ)
0,5 x 1,5 mm (30 mm) (Typ)
DC 10 ... 30 V
≤ 5 Vss
≤ 100 mA
Measures
Reduce the sensing range
Increase the sensing range
Check connection of the test
input. When using female cable
connectors with LED indicators,
make sure the test input is
assigned correspondingly.
1)
2)
8025302.1BBX / 2021-05-12 | SICK
Subject to change without notice

Publicidad

Tabla de contenido
loading

Tabla de contenido