Technical Data; Electrical Safety - Ferm PDM1046 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
accessory is larger than or the same as the
maximum speed of the machine. Refer to the
rating plate on the machine.
• Before use, remove all nails and other metal
objects from the workpiece.
• Make sure that the workpiece is properly
supported or fixed.
• Keep your hands away from the workpiece
during use.
• Never put the machine down on a table or a
workbench before it has been switched off.

Electrical safety

Always check that the voltage of the
power supply corresponds to the voltage
on the rating plate.
• Do not use the machine if the mains cable or
the mains plug is damaged.
• Only use extension cables that are suitable
for the power rating of the machine with a
minimum thickness of 1.5 mm
extension cable reel, always fully unroll the
cable.
Mains plug replacement (UK only)
If the moulded 3-pin plug attached to the unit is
damaged and needs replacing, it is important
that it is correctly destroyed and replaced by an
approved BS 1363/5A fused plug and that the
following wiring instructions are followed.
The wires in the mains cable are coloured in
accordance with the following code:
blue neutral
brown live
As the colours of the wires in the mains cable
of the unit may not correspond to the coloured
markings identifying the terminals in the plug,
proceed as follows:
- The wire which is coloured blue must be
connected to the terminal which is marked
with the letter N or coloured black.
- The wire which is coloured brown must be
connected to the terminal which is marked
with the letter L or coloured red.

TECHNICAL DATA

Mains voltage
Mains frequency
Power input
No-load speed
Impact rate
Max. drill bit diameter
Protection class
Weight
Noise and vibration
Sound pressure (Lpa)
Acoustic power (Lwa)
Uncertainty (K)
Impact drilling mode
Drill into metal
Uncertainty (K)
. If you use a
2
Vibration level
The vibration emission level stated in this
instruction manual has been measured in
accordance with a standardised test given in
EN 60745; it may be used to compare one tool
with another and as a preliminary assessment of
exposure to vibration when using the tool for the
applications mentioned
- using the tool for different applications, or with
different or poorly maintainted accessories,
may significantly increase the exposure level
- the times when the tool is switched off or when
it is running but not actually doing the job, may
significantly reduce the exposure level
Protect yourself against the effects of vibration by
maintaining the tool and its accessories, keeping
your hands warm, and organizing your work
patterns
V~
Hz
W
min-1
min-1
Wood
Concrete
Steel
kg
dB(A)
dB(A)
dB(A)
m/s2
m/s2
m/s2
Wear hearing protection.
PDM1046
230
50
500
0 - 3,000
0 - 48,000
mm 25
mm 13
mm 10
IP 20
1.8
PDM1046
97.7
108.7
3
18.64
2.98
1.5
5

Publicidad

Tabla de contenido
loading

Tabla de contenido