10. Fault rectification

Call on the services of a trained electrician
any time there is a fault. Repairs should only
be carried out by a trained electrician.
Danger to life from electric
shock when working on
electrical equipment!
DANGER
Prior to access to the connection
terminals, switch off all supply
circuits. Switch off mains fuse,
secure against being accidentally
switched back on and position a
visible warning sign.
A fault can occur if, for example, the air-
stream temperature increases or if the fan
motor is blocked.
If the fan motor overheats, the
thermal overload protection reacts.
In the case of thermal overload, it
switches the motor off and
automatically turns it on again after
the motor has cooled down.
1. Let the fan motor cool down.
2. Check if the mains fuse is switched on
and if the fan starts independently after
cooling.
3. If necessary, clean the unit according to
the instructions in Chapter 9.
4. Ensure the environmental conditions
according to Chapter 4.
5. If the fault still continues or occurs again,
switch off at the mains fuse and call on the
services of a trained electrician.

11. Spare parts

Spare parts may only be sourced
from and fitted by a specialist
installer.
Item
Designation
1
Shutter,
complete
2
Connecting
flange, complete
Type
Article no.
15
0059.0144.9000
15 P
15
E059.0140.9000
10. Fault rectification │ gb
2
Connecting
flange, complete
2.1
Motor with
screws
2.2
Impeller with
clamping ring
3
Internal
housing,
complete
3
Internal
housing,
complete
13
Pull-switch,
complete
In the case of questions:
Maico Elektroapparate-Fabrik GmbH
Steinbeisstraße 20,
78056 Villingen-Schwenningen, Germany
Tel. +49 (0)7720 694445 / Fax +49 (0)7720
694175, E-Mail: ersatzteileservice@maico.de

12. Dismantling

Dismantling may only be undertaken
by a trained electrician ( Chap. 1).
Danger to life from electric
shock.
Prior to access to the connection
DANGER
terminals switch off all supply
circuits. Switch off mains fuse,
secure against being accidentally
switched back on and position a
visible warning sign.

13. Disposal

Do not dispose of in domestic
waste.
The unit contains in part materials
that can be recycled and in part
substances that should not end up
in the domestic waste.
Dispose of the unit once it has reached
the end of its service life according to the
regulations valid where you are.