Environmental Conditions And Operating Limits; Technical Data; Safety Instructions - Maico EVN 15 Instrucciones De Montaje

Ventilador de ventana
Ocultar thumbs Ver también para EVN 15:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
3.1 Unit Overview, Fig. A to F
1
Shutter, complete
1.1 Lamella
2
Connecting flange with
2.1 Motor and
2.2 Impeller
3
Internal housing
4
Terminal box cover
5
Screw, M5 x 50 mm
6
Adhesive strip
7
Gluing point
8
Lock nut
9
Socket spanner, width across flats 8, red
10 Tension relief
11 Self-sealing grommet
12 Terminal block
13 Pull-switch
S
Window cut-out or wall cut-out
3.2 Intended use
● The unit is only intended for domestic use
and similar purposes.
● The unit serves for air extraction of
restaurants, showrooms, lecture halls,
kindergartens, hospitals, foreman's offices
and similar rooms.
● Operation is only permitted with:
● installation in flat glass windows with
single or double glazing.
● installation in thin walls with a pane or
wall thickness from 3...30 mm.
● installation in a vertical position.
● an installed shutter and fitted housing.
3.3 Foreseeable cases of misuse
Maico is not liable for damages caused by
use contrary to the intended purpose. Under
no circumstances should the unit be
used:
● in hinged double-glazed windows.
● on ceilings, sloping roofs or sloping walls.
● close to flammable materials, liquids or
gases.
3. Product information │ gb
● to convey chemicals, aggressive gases
or vapours.
● in explosive atmosphere.
● for air extraction of kitchen exhaust.
Never dismantle the shutter [1].
4. Environmental conditions and
operating limits
● Permissible maximum air temperature
40 °C.
● Sufficient supply air intake must be
ensured during operation with air-
ventilated fireplaces. The maximum
permitted pressure difference per living
unit is 4 Pa.

5. Technical data

See rating plate.

6. Safety instructions

6.1 General
● Read through these operating
intructions carefully before
assembly and commissioning.
● Assembly and electrical con-
nection may only be underta-
ken by trained specialists in
accordance with Chapter 2.1.
● With electrical and unit install-
lation, the relevant regulations
must be observed, particularly
DIN VDE 0100 with the cor-
responding parts. In rooms
with baths or shower units,
e. g., this would be Part 701.