Releasing the chain brake
Pull the hand guard as far as
N
possible toward the handlebar
(position ‚) – chain brake is
released
Checking the chain brake for proper
functioning
Each time before starting work:
Insert the battery in the unit
N
Release the chain brake – pull the
N
hand guard toward the handlebar
(position ‚)
Switch on the device –
N
simultaneously press and hold
down the trigger switch lockout and
trigger switch
Press the hand guard forward
N
towards the tip of the bar
(position ƒ) – saw chain is stopped
The chain brake is OK if the saw chain is
stopped within fractions of a second.
The hand guard must be free of dirt and
easily moveable.
MSA 160 T
Connecting Charger to
Power Supply
Power supply (mains) voltage and
operating voltage must be the same.
Insert the plug (1) in the wall
N
outlet (2).
1
A self test is performed after the charger
is connected to the power supply. During
this process, the light emitting diode (1)
on the charger lights up green for about
1 second, then red and goes off again.
Charging the Battery
A factory-new battery is not fully
charged.
Recommendation: Fully charge the
battery before using it for the first time.
2
Connect the charger to the power
1
N
supply – mains voltage and
operating voltage of the charger
must be the same – see
"Connecting Charger to Power
Supply".
Operate the charger only in enclosed
and dry rooms at ambient temperatures
between +5°C to +40°C (+41°F to
+104°F)
Only charge dry batteries. Allow a damp
battery to dry before charging.
Push the battery (1) into the
N
charger (2) until noticeable
resistance is felt – then push it as far
as stop.
English
2
59