Display shown
<HK2>
Parameters
Operating mode heating
>Auto
Set value day
Night set back temp.
>Select operating mode
Table 5.1 Settable parameters in the operator level (contd.)
Operating Manual geoTHERM VWS/VWW 0020051578_01
All manuals and user guides at all-guides.com
Description
The room set target temperature is the tempera-
2
ture to which the heating should be regulated in the
operating mode "Heat" or during the time slots.
22 °C
Note: Select a room temperature that is just high
15 °C
enough to ensure your personal well-being
(e.g. 20 °C). Each degree over and above the set
value means an increase in energy consumption of
around 6 % per annum.
The set-back temperature is the temperature to
which the heating is regulated during the set-back
period. An individual set-back temperature can be
set for each heating circuit.
The set operating mode determines under which
conditions the assigned heating circuit or hot water
circuit should be regulated.
The following operating modes are available for
heating circuits:
Auto: The operation of the heating circuits alter-
nates between the Heating and Energy Saving
operating modes in accordance with a settable timer
programme.
Eco: The operation of the heating circuits alternates
between the Heating and Off operating modes in
accordance with a settable timer programme. The
heating circuit is switched off during the set-back
period provided the frost protection function
(which depends on the outside
temperature) is not activated.
Heating: The heating circuit operates at the room
set target temperature regardless of any settable
timer programme.
Energy sav: The heating circuit operates at the set-
back temperature regardless of any settable timer
programme.
Off: The heating circuit is off, provided that the frost
protection function (depending on the external tem-
perature) is not activated.
Note:
Additional heating circuits are displayed, depending
on the system configuration.
Operation 5
Factory setting
Room set target
temp.: 20 °C
Set-back temp.:
15 °C