7 Appendix
Description
Hydraulic connections
- Heating circuit flow and return
- Heat source flow and return
Heat source circuit
- max. operating pressure
- min. inlet temperature
- max. inlet temperature
- Nominal flow rate dT 3 K
- Residual head dT 3 K
- Nominal flow rate dT 4 K
- Residual head dT 4 K
- Electrical power consumption - pump
CH circuit
- max. operating pressure
- min. flow temperature
- max. flow temperature
- Nominal flow rate dT 5 K
- Residual head dT 5 K
- Nominal flow rate dT 10 K
- Residual head dT 10 K
- Electrical power consumption - pump
refrigerant circuit
- Coolant type
- Quantity
- Permissible operating overpressure
- Compressor type
- Oil
- Oil filling capacity
Heat pump performance data
W10W35 dT5
- Heating output
- Power consumption
- Performance figure/COP
W10W35 dT10
- Heating output
- Power consumption
- Performance figure/COP
W10W55
- Heating output
- Power consumption
- Performance figure/COP
Internal sound level
Conforms to safety regulations
Tab. 7.2 Technical data - VWW (contd.)
All manuals and user guides at all-guides.com
Unit
VWW 220/2
mm
mm
MPa (bar)
°C
°C
l/h
6417
mbar
" - "
l/h
4813
mbar
" - "
W
" - "
MPa (bar)
°C
°C
l/h
5099
mbar
106
l/h
2603
mbar
31
W
" - "
-
kg
4.3
MPa (bar)
-
-
l
4
kW
29.9
kW
5.8
-
5.2
kW
30.2
kW
5.5
-
5.5
kW
26.9
kW
7.6
-
3.5
dBA
63
-
VWW 300/2
VWW 380/2
G 1 1/2"
G 1 1/2"
" - "
" - "
" - "
8760
10800
" - "
" - "
6570
8100
" - "
" - "
" - "
" - "
0.3 (3)
25
62
6960
8700
152
198
3600
4500
45
58
" - "
" - "
R 407 C
5.99
6.7
2.9 (29)
Scroll
Ester
4
4.14
41.6
52.6
7.8
9.8
5.3
5.3
42.4
52.3
7.5
9.4
5.7
5.5
37.2
47.4
10.4
12.9
3.6
3.6
63
63
CE-1027 mark
Low Voltage Directive 73/23/EWG
EMC Directive 89/336/EWG
EN 60335
ISO 5149
Pressure equipment directive 97/23/EC, category II
VWW 460/2
13080
" - "
9810
" - "
" - "
10440
251
5520
76
" - "
8.6
4.14
63.6
12.4
5.1
64.7
12.0
5.4
57.3
15.8
3.6
65