Kohler Dual Opto 1103128 Instrucciones De Servicio página 13

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Calibration
Code
Remove the Old Circuit Board
Press on each end of the circuit board near the clasps and push
the circuit board toward the inside of the case.
Remove and discard the old circuit board.
Install the New Circuit Board
Place the new circuit board between the two grooves at the
bottom of the case and tilt toward the outside of the case until the
board snaps into the clasps.
Connect the motor, solenoid, and thermistor wiring looms to the
new circuit board.
Read and record the three digit calibration code found on the
valve assembly label.
Kohler Co.
Clasp
Press here.
Circuit
Board
13
Press
here.
1117891-9-B

Publicidad

Tabla de contenido
loading

Tabla de contenido