• The tungsten carbide teeth should be checked regularly
for sharpness and tooth breakages, and repaired or re-
sharpened as required. Note that when re-sharpening,
the bevel angles on the front of the teeth should
be retained. The tungsten carbide teeth should be
checked regularly for sharpness and tooth breakages,
and repaired or re-sharpened as required. Contact the
manufacturer.
CLEANING
1. Keep the tool's air vents unclogged and clean at all
times.
2. Remove dust and dirt regularly with a cloth or soft
brush.
3. Never use caustic agents to clean plastic parts. A damp
cloth is recommended. Water must never come into
contact with the saw.
4. Re-lubricate all moving parts at regular intervals.
BRUSH REPLACEMENT
• The carbon brushes are a consumable item which
should be inspected periodically and replaced when
worn.
TROUBLESHOOTING
SYMPTOM
Saw will not operate
Poor performance
GB
12

Maintenance / Troubleshooting

All manuals and user guides at all-guides.com
PROBLEM
Power lead not plugged in
Power fault, fuse or circuit breaker
tripped
Brushes worn or sticking
Lead damaged
Faulty switch
Faulty motor
Extension lead too long
or undersized
Blunt or damaged blade
Motor is overloaded
Tool is overheating
• With the saw disconnected from power, unscrew the
brush caps located near the end of the motor. Remove
the brushes by pulling carefully on the protruding
springs.
• If either brush is worn to less than 6mm long, both
brushes must be replaced using genuine Triton
replacement brushes - available from Authorised Triton
Saw Repair Centres.
• Triton Precision Power Tools will not be responsible
for any damage or injury caused by mishandling or
unauthorised repair of this tool.
POWER LEAD MAINTENANCE
If the power lead needs replacing, the task must be carried
out by the manufacturer, the manufacturer's agent, or an
authorised service centre in order to avoid a safety hazard.
SUGGESTED REMEDY
Ensure that the power lead is connected to
the power supply
Check the power supply
Disconnect power, open brush caps and ensure
brushes move freely in the holders. Check
whether brushes require replacing as outlined in
the maintenance section.
Use authorised service centre**
to repair or replace the lead
Use authorised service centre**
to repair or replace the switch
Use authorised service centre**
to repair or replace the motor
Use extension lead heavy enough
to carry the current
Re-sharpen or replace blade
Reduce pushing force on saw. Ensure the cut
isn't closing and pinching the blade.
Turn off the tool and let it cool down to
room temperature. Inspect and clean the
ventilation slots.