Messages
15 Messages
15.1 Status messages
An error code is displayed in the 7 segment display in
event of an error.
The status message can be deleted by pressing the
Electrode/TIG button.
Code
Note
EEProm write/read error
H06
15.2 Error messages
An error code is displayed in the 7-segment display in
the event of a malfunction. Press the Menu button to
display the Sub-Code.
Code
Error
E01
Thermal overload
E02
Power section
E03
Current sensor
E06
Primary current trans-
former
E07
Supply voltage 15V
E13
Control panel
E14
Control panel
09.16
Cause
Communication with EEProm faulty Switch machine off and on again, ex-
Cause
Duty cycle exceeded
Fan defective
Power section start-up faulty
Current sensor defective
Current difference between transformer
and sensor is too high
Fault internal supply voltage
Component group control panel faulty
Component group control panel faulty
909.2779.9-00
After the message has been output, the ma-
i
chine will only function to a limited extent; the
error must be corrected as quickly as pos-
sible.
Possible remedy
ecute master reset
As long as there is an error code on display
i
welding is not possible.
Allow switched-on machine to cool
down for a few minutes.
Check the fan: Switch unit on and
off, fan must start up for a short
period,
Inform Service
Inform Service
Inform Service
Inform Service
Inform Service
Inform Service
Possible remedy
- 29 -