Messages
17
Messages
17.1
Information and error messages Handy 160 ControlPro
Code
Symptom
H06
EEProm write/read error
E01
Thermal overload
E02
Power section
E03
Current sensor
E06
Primary current transformer Current difference between transform-
E07
Supply voltage 15V
E13
Control panel
E14
Control panel
17.2
Error messages Handy 180
Symptom
LED mains 36 and LED malfunc-
tion 35 are not lit
LED mains 36 is lit and LED mal-
function 35 flashes
LED mains 36 is lit, but no welding
current
LED malfunction 35 is lit con-
stantly
05.11
Cause
Communication with EEProm faulty
Duty cycle exceeded
Fan defective
Power section start-up faulty
Current sensor defective
er and sensor is too high
Fault internal supply voltage
Component group control panel faulty
Component group control panel faulty
Cause
mains fuse defect
neutral, mains phase missing
machine error
ground cable not connected or de-
fect
electrode holder or torch not con-
nected or defect
machine is overheated, ED ex-
ceeded
Remedy
Switch machine off and on again, execute
master reset
Allow switched-on machine to cool down
for a few minutes.
Switch unit on and off, fan must start up
for a short period, inform service.
Inform Service
Inform Service
Inform Service
Inform Service
Inform Service
Inform Service
Remedy
exchange mains fuse
check mains cable / mains extension cable
Turn off machine, wait until LED mains 36 is off,
turn machine on again If malfunction still persits,
contact Service
check ground cable, exchange if necessary
check electrode holder or torch, exchange if
necessary
let machine cool down in standby