Messages; Informative Messages - LORCH ControlPro T Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 58

Messages

Technical data*
Current input I1 no-load
Mains fuse slow-response TIG/EL
Phase angel cos φ I2 max
Powerfactor λ at I2 max
Max. permissible system impedance Zmax in
acc. with IEC 61000-3-11/-12
Recommended generator performance
Machine
Protection class
Insulation class
Cooling method
Noise emission
Norm
Designation
Dimensions and weights
Dimensions power source (LxWxH)
Weight of power source
Tab. 9:
Technical data
ED = Switch-on duration
*) measured at 40° C environmental temperature
18
Messages
18.1

Informative messages

After the message has been output, the
i i
machine will only function to a limited ex-
tent; the error must be corrected as quickly
as possible.
Code
Note
H01
Undervoltage
H03
Fans
H04
PFC
H05
EEProm checksum error
H06
EEProm write/read error
H10
Torch protection
Tab. 10: Informative messages
04.19
Units
T 250 DC
ControlPro
A
0,15
A
16
cos φ
0,97
λ
81
kVA
> 13 / 3 ~
IP
23S
B
F
db(A)
< 70
EN 60974-1
CE, S
mm
430 x 185 x 326
kg
14,3
Cause
Mains voltage too low
Fan fault
PFC faulty
Communication with EEProm faulty
Communication with EEProm faulty
Torch doesn't send ID although torch
protection is activated
909.1709.9-05
Machine type
T 300 DC
T 250 AC/DC
ControlPro
ControlPro
0,15
0,15
16
16
0,97
0,97
67
76
> 16 / 3 ~
> 13 / 3 ~
23S
23S
B
B
F
F
< 70
< 70
EN 60974-1
EN 60974-1
CE, S
CE, S
483 x 185 x 326
14,5
16,3
Possible remedy
Check mains voltage
Inform Service
Inform Service
Switch machine off and on again, execute
master reset
Switch machine off and on again, execute
master reset
Adjust torch-ID
T 300 AC/DC
ControlPro
0,15
16
0,97
94
> 16 / 3 ~
23S
B
F
< 70
EN 60974-1
CE, S
16,3
- 55 -

Publicidad

Tabla de contenido
loading

Tabla de contenido