Adjust cleaning temperature
Set device switch to desired tempera-
ture.
Set working pressure and flow rate
Pressure/quantity regulation of the
pump unit
Turn the regulation spindle in a clock-
wise direction: Increase working pres-
sure (MAX).
Turn the regulation spindle in an anti-
clockwise direction: Reduce working
pressure (MIN).
Operation with detergent
– For considerate treatment of the envi-
ronment use detergent economically.
– The detergent must be suitable for the
surface to be cleaned.
With support of the detergent dose
valve set detergent concentration as
determined by the manufacturer.
Note: Recommended values at the control
panel at maximum working pressure.
Note: If detergent is be suctioned from an
external container, route the detergent suc-
tion hose through the recess to the outside.
Set pressure/temperature and deter-
gent concentration according to the sur-
face to be cleaned.
Note: To prevent damage due to too much
pressure, always position high pressure ray
first from a greater distance towards object
to be cleaned.
Recommended cleaning method
– Loosen the dirt:
Spray detergent economically and let it
work for 1...5 minutes but do not let it
dry up.
– Remove the dirt:
Spray off loosened dirt with the high
pressure jet.
26
Cleaning
Operating with cold water
Removal of light contaminations and clear
rinse, i.e.: Gardening tools, terrace, tools,
etc.
Set operating pressure according to
need.
The appliance works in the most economi-
cal temperature range (max. 60°C).
Operating with hot water
DANGER
Scalding danger!
Set device switch to desired temperature.
We recommend the following cleaning tem-
peratures:
– Light contaminations
30-50 °C
– Contaminations containing protein, i.e.
in the food processing industry
max. 60 °C
– Vehicle cleaning, machine cleaning
60-90 °C
After operation with detergent
Set dosing value for detergent to "0".
Set the appliance switch to "1" (opera-
tion with cold water).
Open the hand spray gun and rinse the
appliance for at least 1 minute.
Turn off the appliance
DANGER
Danger of scalding by hot water. After oper-
ation with hot water, the device must be op-
erated with open end handgun with cold
water for at least two minutes.
Set the appliance switch to "0/OFF".
Shut off water supply.
Open the hand spray gun.
Turn on pump shortly (appr. 5 seconds)
with device switch.
Pull main plug out of socket with dry
hands only.
Remove water connection.
Activate hand spray gun until device is
pressure less.
Lock the trigger gun.
– 7
EN
Eco level