Continuity Test
Cont. Threshold
40Ω (approx.)
Diode Test
Test Current
0.6mA
Capacitance
Ranges
4, 40, 400nF; 4, 40µF
Accuracy
Range
4nF
40nF
400nF
4µF
40µF
All manuals and user guides at all-guides.com
Cont. Indicator
2kHz (tone)
Open Circuit Voltage
3.0V DC (approx.)
Resolution
1pF in 4nF range
Accuracy in Relative Mode
± (1% + 4 digits)
± (1% + 4 digits)
± (1% + 4 digits)
± (1% + 4 digits)
± (1% + 4 digits) (≤20µF)
± (5% + 8 digits) (>20µF)
93-105 / 00408
Input Protection
600V DC or RMS AC
Input Protection
600V DC or RMS AC
Input Protection
600V DC or RMS AC
19