Electrical Connection - Balluff BTL BNC 00 C15A 0-000S32 Serie Instrucciones De Montaje

Sistema magnetostrictivo de medición de posición
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14
BTL B/ZNC_ 00- _ _ _ _ -C15A _ _ _0-000S32/C_ _000
Magnetostrictive Linear Position Sensor – Rod Style

Electrical Connection

Depending on the model, the electrical connection is made
using a cable or a connector.
Note the information on shielding and cable
routing.
Plug connection S32
Pin
C15AA/A1...
C15AE/A5...
1
Not used
Output 1
2
0 V
3
Output 2
4
C/Q
1)
5
Output 1
Not used
6
GND
2)
7
10...30 V
8
Not assigned
3)
1) only for configuration via IO-Link
2) Reference potential for supply voltage and EMC-GND
3) Unassigned leads that are not used can be connected to the GND on
the controller side but not to the shield.
Cable connection
Color
GY gray
PK pink
WH white
GN green
BU blue
BN brown
1) only for configuration via IO-Link
2) Unassigned leads that are not used can be connected to the GND on
the controller side but not to the shield.
www.balluff.com
Pin assignment
of S32 (view
from above on
BTL)
Signal
0 V
Output 2
C/Q
1)
Output 1
GND
2)
10...30 V
Shielding and cable routing
Defined ground!
The BTL and the control cabinet must be at the
same ground potential.
Shielding
Observe the following instructions to ensure
electromagnetic compatibility (EMC):
Connect BTL and controller using a shielded cable.
Shielding: Braided copper shield with minimum 85%
coverage.
Shield is internally connected to connector housing.
Magnetic fields
The position measuring system is a magnetostrictive
system. Ensure that there is sufficient distance between
the BTL and the transducer/holding cylinder and strong,
external magnetic fields.
Cable routing
All cables between BTL, control and power supply must
be routed tension-free. In order to avoid electromagnetic
interference, ensure sufficient distance to cables carrying a
heavy current and cables with high-frequency voltage
signals (e.g. of frequency converters).
Only approved cables with a minimum size of
AWG 24 may be used. All connected cables
must have a temperature resistance of at least
85 °C. Use copper conductor, only.
Cable length
BTL ...-C15AA/A1...
BTL ...-C15AE/A5...
1) Prerequisite: Construction, shielding and routing preclude the effect of
any external noise fields.
Max. 30 m
1)
Max. 100 m
1)
english
3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Btl bnc 00 c15a 0-c 000 serieBtl znc 00 c15a 0-000s32 serieBtl znc 00 c15a 0-c 000 serieBtl bnc 00 serieBtl znc 00 serie

Tabla de contenido