Installation and connection (continued)
5.4
Electrical connection
Depending on the model, the electrical connection is made
using a cable or a connector. The connection or pin
assignments for the respective version can be found in
Tab. 5-2 to Tab. 5-5.
See the information about Shielding and cable
routing on page 13.
5.4.1
Connectors
S15 connector
Fig. 5-9:
Pin assignment of S15 (view from above on BTL)
Pin
1
0 V (output 2)
2
0 V (output 1)
3
Output 2
4
C/Q
5
Output 1
6
GND
1)
7
10...30 V
8
Not used
)2
Reference potential for supply voltage and EMC-GND.
1)
Unassigned leads that are not used can be connected to the GND on
2)
the controller side but not to the shield.
Tab. 5-2:
Pin assignment S15
12
english
Signal
S32 connector
Fig. 5-10: Pin assignment of S32 (view from above on BTL)
Pin
C15AA/A1...
1
Not assigned
1)
2
3
4
5
Output 1
6
7
8
Not assigned
Unassigned leads that are not used can be connected to the GND on
1)
the controller side but not to the shield.
Reference potential for supply voltage and EMC-GND.
2)
Tab. 5-3:
Pin assignment S32
S35 connector
Fig. 5-11: Pin assignment of S35 (view from above on BTL)
Pin
C15AA/A1...
1
Output 1
2
0 V (output 1)
3
Output 2
4
0 V (output 2)
5
6
Unassigned leads that are not used can be connected to the GND on
1)
the controller side but not to the shield.
Reference potential for supply voltage and EMC-GND.
2)
Tab. 5-4:
Pin assignment S35
C15AE/A5/AC...
Output 1
0 V
Output 2
C/Q
Not assigned
1)
GND
2)
10...30 V
1)
C15AE/A5/AC5...
Output 1
0 V
Not assigned
1)
Not assigned
1)
10...30 V
GND
2)