BTL6-P510-M _ _ _ _ -E2/E28-KA _ _ /LA _ _
Magnetostrictive Linear Position Sensor – Rod Style

Electrical connection

Color
Control and data signals
YE Yellow
PK Pink
GY Gray
GN Green
Supply voltage (external)
BU Blue
BN Brown
Shielding and cable routing
Defined ground!
The BTL and the control cabinet must be at the
same ground potential.
Shielding
To ensure electromagnetic compatibility (EMC), observe
the following:
Connect BTL and controller using a shielded cable.
Shielding: Braided copper shield with minimum 85%
coverage.
Cable version: On the BTL side, the cable shielding is
connected to the housing. Ground the cable shielding
on the controller side (connect with the protective earth
conductor).
Strand version: Observe note on shielding.
Magnetic fields
The position measuring system is a magnetostrictive
system. Ensure that there is sufficient distance between
the BTL, holding cylinder and strong, external magnetic
fields.
Cable routing
Do not route the cable between the BTL, controller, and
power supply near high voltage cables (inductive stray
noise is possible). The cable must be routed tension-free.
Min. bending radius (BTL6-...-KA_ _)
Fixed routing
Moved routing
Cable length
The maximum cable length is 50 m
4) Prerequisite: Construction, shielding and routing preclude the effect of
any external noise fields.
www.balluff.com
Signal
+Init
−Init
+Start/Stop
−Start/Stop
GND
10...30 V DC
5 x cable Ø
15 x cable Ø
4)
.
Installation
NOTICE!
Interference in function
Improper installation can compromise the function of the
BTL and result in increased wear.
► The mounting surface of the BTL must make full
contact with the supporting surface.
► The bore must be perfectly sealed (O-ring/flat seal).
The BTL can be fastened in a fitting bore (Ø 48 H8), but
must be sealed with the provided O-ring and support ring.
The body of the BTL is fastened using 3 M5 threaded pins
at a 120° angle.
For horizontal assembly with nominal lengths > 500 mm,
support the rod and tighten it at the end if necessary (only
possible with a diameter of 10.2 mm).
If installed in a hydraulic cylinder, the magnet should not
make contact with the rod. Minimum bore diameter in the
support piston:
Rod diameter
10.2 mm
8 mm
Startup
DANGER
Uncontrolled system movement
When starting up, if the position measuring system is
part of a closed loop system whose parameters have not
yet been set, the system may perform uncontrolled
movements. This could result in personal injury and
equipment damage.
► Persons must keep away from the system's
hazardous zones.
► Startup must be performed only by trained technical
personnel.
► Observe the safety instructions of the equipment or
system manufacturer.
1. Check connections for tightness and correct polarity.
Replace damaged connections.
2. Turn on the system.
3. Check measured values and adjustable parameters
(especially after replacing the BTL or after repair by the
manufacturer). Recalibrate the BTL, if necessary.
Operating notes
Regularly check function of the BTL and all associated
components.
Take the BTL out of operation whenever there is a
malfunction.
Secure the system against unauthorized use.