Note 4: Timing can be set in continuous mode. After entering the weekly timer and window open from the
continuous mode, you must turn it off before re-entering the continuous mode and the default mode is cold air.
Timing mode:
Scheduled start: In standby mode, press "
" to enter scheduled start. The timing indicator "
" turns on (if
timer is set; it is off when no timer is set). Press "
" repeatedly and the digital tube displays "00-12",
corresponding to 0-12 hours (prefix 0 is shown; 00 means no timer). The step is 1 hour. After setting, the digit
flashes 5S and exits (press "
" during flashing to end in advance). The digital tube displays the remaining
OK
time by hour. When reaching the set time, the buzzer beeps once and the heater enters thermostat mode. The
default temperature is 25°C.
Scheduled shutdown: The setting method is the same as above when the heater is working. After the setting is
completed, the digital tube switches back to the state before setting and enters the timer. When reaching the set
time, the buzzer beeps once and the heater automatically shuts off and enters standby.
Note: Timing mode can't coexist with weekly timing. When entering weekly timing from timing mode, the time is
cleared. To enter the timing mode again, you must first turn off the weekly timing.
Thermostat mode
The thermostat mode is that the control device keeps the temperature constant at the target temperature when
the target temperature is set to be higher than the ambient temperature.
a) Press "
/
" to enter temperature setting, the temperature indicator "
" turns on, the default
temperature is 25°C, the setting range is 15°C-35°C, and the step is 1°C. The current set temperature is
displayed and saved after flashing 5 seconds, and the data is lost when the power is turned off.
b) Press "
" to complete the temperature setting.
OK
Working principle: The heater starts running when the temperature is set. When the ambient temperature is
lower than the set temperature, the heater runs in "strong hot air" mode. When reaching the set temperature,
PTC turns off and the level indicator turns off. When the ambient temperature is lower than the set temperature
by 2°C or more, the heater runs in "strong hot air" mod again. The display also corresponds.
Note 1: To turn off the thermostat mode set as above, press the level button to enter the continuous mode.
Note 2: Timing can be set in thermostat mode. After entering the weekly timer and window open mode from
thermostat mode, you must turn it off before re-entering the thermostat mode and the previously set temperature
is displayed after re-entering.
Window open detection mode
Window open detection mode refers that the window open detector is turned on to detect the change of the
ambient temperature and control the equipment switch to achieve the purpose of energy saving.
a) Press "
" to enter window open detection, press it again to turn off window open detection and restore the
default temperature. When window open detection is on, "
" "
" lights up on the display. The default
temperature is 25°C.
b) Press "
/
" to set the temperature. The setting range is 15°C-35°C and the step is 1°C. After setting, the
value is saved and the set temperature is displayed.
Working principle: When the window open detector is turned on and the temperature is set, the heater runs in
thermostat mode according to the set temperature, and starts to detect after reaching the set temperature. If the
temperature drops 5-10°C within ten minutes from a certain moment, the heater will turn off the window open
detector, the window-opening indicator disappears, the buzzer beeps once and the heater enters standby. Press