Vortice MICROCOMFORT T Manual De Instrucciones página 25

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ENGLISH
the power button to turn on the heater again, and the window open detector will turn on. Press the button again
to turn off the window open detector, clear the setting data, and return to previous state.
Note: The temperature set in the window open detection mode may be different from the temperature set in
thermostat mode, but the working principle of temperature control is the same. The window open detection is
added with judgment logic based on the working principle of the thermostat to achieve energy saving and the
data is lost when the power is cut off.
Weekly timing function
Weekly timing refers to setting some time periods and temperatures in each week to let the heater work at the
set temperature within the corresponding time. The setting process is:
Set current week and time-> Enter weekly timing -> Set the day of weekly timing (DAY1) -> Set time period of
weekly timing (P1) -> Set weekly timing
Start time (ON) -> Set end time of weekly timing (OFF) -> Set temperature of weekly timing (°C) -> Weekly timing
starts work
Set current time:
a) Press the "
" button to enter time setting. Press the "
" button repeatedly to switch the display on the
SET
SET
digital tube in the following sequence:
Settimana
Ora
Minuti
Stato prima dell'impostazione
Default: Monday 12:30, showing: "d1"-> "12"-> "30".
b) Press the "
/
" to adjust, the digital tube flashes 5S to complete the setting and exit (press "
" during
OK
flashing to confirm and exit) to the original state.
1) When setting the day of the week, the digital tube displays "d1-d7", corresponding to Monday to Sunday.
2) When setting the hour, the digital tube displays "00-23", corresponding to 0-23 hours.
3) When setting the minutes, the digital tube displays "00-59", corresponding to 0-59 minutes.
Note: Press the "SET" button repeatedly in any state to query the day of the week. The time data currently set
is lost when the power is cut off.
Set weekly timing:
When the heater is working, press "
" to turn on the weekly timing and the indicator "
" lights up; when
P
the button is pressed again, the indicator turns off.
Note 1: If the window open detector is turned on during weekly timing, the window open detector can only be
used when the heater is turned on, and the window open mode is prioritized. When the heater enters standby
mode, you need to manually press the power button to re-enable the weekly timing and window open function.
Note 2: The standby state is different from the weekly timing standby state. In standby state, the digital tube
only displays "SS". In weekly timing standby state, the PTC and the fan are turned off. If the data isn't set when
the heater power and the weekly timing are turned on, the heater is in weekly timing standby state and the
weekly timing indicator turns on.
1) Before setting the weekly timing, make sure the date and time are set.
2) Press "
P
" to turn on weekly timing.
DAY
3) Press "
" to display "d1" on the digital tube, press "
" repeatedly to display "d1-d7", corresponding to
DAY
Monday to Sunday.
25

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

70872

Tabla de contenido