Cleaning And Maintenance - Sime RS MK II Serie Manual Del Usuario

Ocultar thumbs Ver también para RS MK II Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
.
–. In.the.event.of.malfunctioning.or.breakdown,.turn.off.the.boiler,.and.do.not.attempt.to.repair.it.yourself..Contact.your.local.au-
thorised.technical.service.centre..
–. Boiler.installation.and.all.other.service.and.maintenance.operations.must.be.performed.by.qualified.personnel..Never.tamper.
with.any.of.the.devices.which.the.manufacturer.has.sealed.
–. Never.obstruct.the.air.intake.grids.or.the.ventilation.openings.in.the.room.in.which.the.boiler.is.installed..
TURNING ON AND OPERATING THE BOILER
TURNING ON THE BOILER (fig. 24)
To.turn.on.the.boiler,.simply.set.the.control.
thermostat.knob.(5).to.60°C.and.press.the.
main. switch. (1);. the. boiler. will. start. auto-
matically.
WARNING: When the gas pressure is in-
sufficient, the burner immediately turns
off and the insufficient gas pressure war-
ning signal is enabled (2). In this event, the
boiler cannot be started again using the
release button (6) for safety reasons. The
boiler will automatically start again when
the minimum pressure required by the
gas pressure switch (10 mbar) is restored.
HEATING TEMPERATURE
CONTROL (fig. 24)
Temperature. may. be. controlled. using. the.
thermostat. knob. (5). within. a. range. of. 53.
to.90°C..To.ensure.optimal.performance.of.
the.generator,.do.not.go.below.a.minimum.
operating. temperature. of. 60°C;. . this. will.
prevent. formation. of. condensation. which.
could. cause. the. cast. iron. body. to. deterio-
rate.with.time..
RELEASING THE ELECTRONIC
DEVICE (fig. 24)
"RS Mk II".boilers.have.automatic.ignition.
(with. no. pilot. light). and. have. an. SM. 191.1.
electronic.control.and.protection.device..
The. boiler. starts. when. the. main. switch.
(1). is. pressed,. sending. discharge. current.
to. the. ignition. electrode. through. the. pro-
grammer. while. simultaneously. opening.
the. gas. valve.. . The. burner. will. normally.
ignite.within.1.or.2.seconds..Various.factors.
may.cause.ignition.to.fail,.triggering.the.si-
gnal.which.shuts.down.the.boiler.(1);.if.this.
occurs,.press.the.release.button.(8).and.the.
boiler.will.automatically.start.again..
If.the.boiler.fails.to.ignite.correctly.and.you.
have.already.pushed.the.release.button.two.
or.three.times,.request.the.assistance.of.an.
authorised.service.technician.
TURNING OFF THE BOILER (fig. 24)
To. turn. the. boiler. off. completely,. turn. off.
the.power.using.the.main.switch.(1)...Turn.
58
USER'S INSTRUCTIONS
WARNINGS
1
2
6 3
off.the.gas.supply.cock.if.the.generator.will.
not.be.used.for.some.time.
SAFETY THERMOSTAT (fig. 24)
The. manually. reset. safety. thermostat. (3).
is. tripped. when. the. boiler. temperature.
exceeds.95°C,.shutting.off.the.main.burner.
immediately.. To. start. the. boiler. again,.
remove.the.black.cover.and.reset.the.but-
ton..once.the.boiler.temperature.has.fallen.
below. the. level. to. which. the. thermostat.
is.set.
TRANSFORMATION FOR USE OF
ANOTHER TYPE OF GAS
If.it.is.necessary.to.transform.the.boiler.to.
burn.a.different.type.of.gas,.contact.autho-
rised.SIME.technical.service.personnel..
CLEANING AND MAINTENANCE
At. the. end. of. each. heating. season,. it. is.
essential. to. have. the. boiler. thoroughly.
checked.and.cleaned.out..
Preventive. maintenance. and. checking. of.
the. efficient. operation. of. the. equipment.
5
4
KEY
1.. Main.switch
2.. Gas.pressure.indicator
8
3.. Safety.thermostat
4.. Thermometer
5.. Control.thermostat
6.. Boiler.release.button
8.. Release.button
and. safety. devices. must. be. carried. out.
exclusively. by. the. authorized. technical.
staff.
ATTENTION: Before performing any
work on the boiler, make sure that the
same and its components have cooled in
order to prevent the risk of burns due to
high temperatures.
DISPOSAL OF THE EQUIPMENT
(EUROPEAN DIRECTIVE 2002/96/CE)
Once.it.reaches.the.end.of.its.operating.life,.
the.equipment.MUST.BE.RECYCLED.in.line.
with.current.legislation.
IT.MUST.NOT.be.disposed.of.together.with.
urban.waste.
It.can.be.handed.over.to.recycling.centres,.
if. there. are. any,. or. to. retailers. that. offer.
this.service.
Recycling.prevents.potential.damage.to.the.
environment.and.health..It.allows.to.reco-
ver.a.number.of.recyclable.materials,.with.
considerable. savings. in. terms. of. money.
and.energy.
3
Fig..24

Publicidad

Tabla de contenido
loading