Remove the hexagon shaped cap from the regulator.
2.
Make sure not to dislodge the gasket
the spring
inside the regulator.
Grasp the plastic button stem
3.
fully from the metal cap
The stem snaps snugly into an indent in the cap and
may require a strong pull to remove.
It may be helpful to gently "rock" the plastic stem while
pulling it from the metal cap.
Rotate the stem 180°
4.
The button end of the stem is away from the cap.
a
The letters "LP" on the stem are upside down when the
a
cap is set flat on its head.
Snap the stem back in place in this position inserting it
5.
into the indent in the metal cap
on the cap or
firmly and pull it force-
⁠ .
⁠ .
⁠ .
IMPORTANT: Attach the metallic sticker included with
6.
the conversion kit to the bottom of the appliance as
shown. This sticker provides notice that the appliance
has been converted for use with LP gas. It should be lo-
cated near the appliance rating plate.
→  "Rating plate location", Page 15
If you change the type of gas back to natural gas at a
7.
later point, remove the sticker.
5.2 Replacing the orifices
Remove all burner grates, burner caps and burner
1.
bases.
Replace the orifices with a 7 mm socket wrench. See
2.
burner chart →  Page 14 .
Normal burner with one orifice
Conversion to LP gas en-us