Putting In Service; Principal Of Operation - Stanley 734 AV Serie Manual De Instrucciones

Herramienta hidro-eléctrica
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

O R I G I N A L I N S T R U C T I O N
E N G L I S H

3. PUTTING IN SERVICE

3.1 PRINCIPAL OF OPERATION

IMPORTANT - READ THE SAFETY RULES ON PAGES 4 – 6 AND THE PUMP UNIT INSTRUCTION MANUAL CARE-
FULLY BEFORE PUTTING INTO SERVICE.
When both hoses and control cable are connected to the Avdel® / Enerpac® hydraulic pump unit, the pull and return cycles
of the tool are controlled by depressing and releasing the trigger located in the handle.
When the switch is depressed the solenoid valve, located in the hydraulic pump unit, is energised and directs the pressur-
ised oil flow to the pull side of the piston in the placing tool. This also allows the oil in the return side of the placing tool to
return to the reservoir.
During the pull cycles the piston/collet assembly moves towards the rear of the tool allowing the O-ring type cushion to
push the follower and jaws forward. If a fastener pin has been inserted in the nose assembly, the jaw set will clamp onto the
pintail and assembly will commence.
For Avbolt® and Avdelok® XT the cycle of installation will first clamp the joint to be fastened and then as the anvil continues
to move forward the collar will be swaged into the locking grooves of the pin. At the end of the swaging cycle the anvil will
come up against the joint and as movement continues the pintail will be broken off.
The trigger switch should be released immediately after pin break occurs. Releasing the trigger switch will cause the sole-
noid to de-energise and reverse the flow of pressurised oil.
If the trigger is not released, the placing tool piston will continue to move towards the rear of the tool until it reaches the
end of its stroke. The pressure in the pull side will then increase until a preset 'High Pressure' value is achieved at the pump.
At this point the solenoid valve will automatically de-energise and reverse the flow of pressurised oil to the return side of the
placing tool.
In either case, pressurised oil will now flow into the return side of the placing tool, with the oil in the pull side returning to
the reservoir.
The forward movement of the piston/collet assembly will eject the installed fastener from the anvil.
At the point of releasing the trigger or when the 'High Pressure' value is achieved, the solenoid valve will de-energise and
activate a preset 'Return Timer' . This controls the time that the pump motor will continue run before switching to the idle
mode. The timer can be manually set between 5 and 20 seconds to ensure that the placing tool piston always fully returns to
the forward position (refer to pump manual 07900-01030, pages 10 and 13).
When the piston returns to the fully forward position, the pressure will increase to preset low pressure value - c200bar. The
pump motor will continue to run until the Return Timer has expired. After this time period the motor will stop automatically
and valve will switch to the idle position. The solenoid valve will then automatically cycle to release pressurised oil to the
reservoir from both the pull and return side of the placing tool.
This keeps the installation tool in the forward position. No pressure will be present in the hydraulic system at this point.
The hydraulic pump unit will automatically start up on depression of the tool trigger switch.
9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

73434-02000Av 30

Tabla de contenido