10
Resetting all values (reset)
NOTICE
Interference in function
Resetting the values while the system is running may
result in malfunctions.
► Stop the system before performing the reset.
The reset function can be used to restore all the settings to
the factory settings. For a reset the magnet may also be
located outside the measuring range.
1. Activate buttons
► Hold down any button for at least 3 s.
► Release buttons.
Œ
► Within 1 s hold down
and
for at least 3 s.
⇒ Output indicates error value.
⇒ Buttons are activated.
If an error or an interruption occurs while
activating the buttons, allow a wait time of 12 s
before retrying.
2. Reset
Œ
► Hold down
and
for at least 6 s.
⇒ Output indicates null value.
⇒ All values are reset.
► Release buttons.
⇒ Current position value is displayed.
⇒ Buttons are locked.
www.balluff.com
> 3 s
< 1 s
simultaneously
> 3 s
> 6 s
LED legend:
LED not on
LED green
LED display
Displayed values (example)
LED1 LED2 At 0 to 10 V
1
2
1
2
10.50 V
1
2
LED flashing green
LED 1 and LED 2 flashing green-red
simultaneously
At 4 to 20 mA
5.39 V
10.80 mA
5.39 V
10.80 mA
3.60 mA
0.00 V
4.00 mA
8.43 V
15.67 mA
english