Type C (ø 80/125 coaxial exhaust)
HORIZONTAL EXHAUST
To ensure correct operation of the appliance, do
as follows:
- set the installer parameter PAR 9 as indicated in
table (see point 3.3 to access the installer para-
G
M
meters).
R
STAFFA TELAIO
Maximum length
CALDAIA
exhaust (m)
.
0.-.1,0.
.
1,0.-.2,0.
.
2,0.-.3,0.
.
3,0.-.4,0.
.
4,0.-.5,0.
- proceed with calibrating CO
and minimum capacity as specified in point 4.2.2.
72
NOTES:
- Installation requires the use of a condensation recovery (12) that must be
connected to a water drain siphon (waste water).
- The installation of the coaxial roof exit terminal (4a) requires the removal
of the two ø 60 and ø 100 reducers.
- Before installing accessories, lubricate the internal part of gaskets with
silicon-based products. Avoid using oils and greases.
- Inserting each supplementary 90° elbow reduces the available segment
by 2 metres and Inserting each supplementary 45° elbow reduces the
available segment by 1 metre.
PAR 9
(long chimneys)
Pmin
2
Pmax
3
4
5
6.
at the maximum
2
Model
.
..Murelle.HE.70.R.ErP.
KEY
2.a.
Extension.ø.80/125.L..1000.code.8096171
2.b.
Extension.ø.80/125.L..500.code.8096170
3.
Hinged.tile.code.8091300
4.a.
Coaxial.roof.exit.terminal.code.8091205
10..
Inlet/exhaust.fitting.with.test.outlet.code.8091401
11.
Rubber.gasket.ø.80.(supplied.as.standard)
12..
Condensation.recovery.ø.80.L..135.code.8092800
13..
Coaxial.exhaust.ø.80/125.L..885.code.8091210
14.a.. 90°.curve.ø.80/125.code.8095870
14.b. 45°.curve.ø.80/125.code.8095970
H (m)
L (m)
8.
5
Fig..8