3...Visualizzazione.temperatura.sonda
.....sanitario.(SS).solo.per.caldaie.istantanee
4. .Visualizzazione.temperatura.sonda
.....ausiliaria.o.sonda.bollitore.(SB)
2.6.1 MODBUS mode
5...Visualizzazione.temperatura
.....sonda.fumi
This. mode. allows. for. MODBUS. commu-
nication.of.at.least.two.boilers.in.cascade.
and.is.performed.by.requesting.MODBUS.
INTERFACE.KIT.code.8092278.
6..Visualizzazione.temperatura
.....riscaldamento.riferita.al.primo.circuito
2.7
ELECTRICAL
CONNECTION
7..Visualizzazione.temperatura
The. boiler. is. supplied. with. an. electric.
.....riscaldamento.riferita.al.secondo.circuito
cable.. Should. this. require. replacement,.
it. must. be. purchased. exclusively. from.
SIME..
The. electric. power. supply. to. the. boiler.
must.be.230V.-.50Hz.single-phase.throu-
8...Visualizzazione.corrente
.....di.ionizzazione.in.µA
gh. a. fused. main. switch,. with. at. least. 3.
mm.spacing.between.contacts..
Respect. the. L. and. N. polarities. and. the.
earth.connection.
NOTE: SIME declines all responsibili-
ty for injury or damage to persons,
animals or things, resulting from the
11...Visualizzazione.numero.di.accensioni.del.bruciatore.x.1.000.(es..97.000.e.500)
12...Visualizzazione.codice.errore
.......ultima.anomalia
failure to provide for proper earthing of
the appliance.
13...Visualizzazione.codice.errore
.......penultima.anomalia
2.7.1
Chronothermostat connection
Connect.the.chronothermostat.as.indica-
14...Visualizzazione.numero.totale
.......delle.anomalie
ted.in.the. boiler. electrical.diagram.(see
fig. 11) after.having.removed.the.existing.
bridge..
The. chronothermostat. to. be. used. must.
15...Contatore.accessi.parametri
be.of.a.class.conforming.to.the.standard.
.......installatore.(es..140.accessi)
EN.607301.(clean.electrical.contact).
2.7.2
Remote control SIME HOME
connection (optional)
16...Contatore.accessi.parametri
.......OEM.(es..48.accessi)
The. boiler. is. designed. for. connection. to.
a. remote. control. unit. SIME.HOME,. sup-
plied.on.request.(code.8092281)..
The. remote. control. unit. SIME.HOME.
allows. for. complete. remote. control. of.
the.boiler..
The.boiler.display.will.show.the.following.
message:
For. installation. and. use. of. the. remote.
control,. follow. the. instructions. in. the.
package.
NOTE: Ensure PAR 10 set to 1 (PAR 10
= 1).
2.7.3
External sensor connection
The. boiler. is. designed. for. connection. to.
an. external. temperature. sensor,. sup-
plied. on. request. (code. 8094101),. which.
can.automatically.regulate.the.tempera-
ture.value.of.the.boiler.output.according.
to.the.external.temperature.For.installa-
tion,.follow.the.instruction.in.the.packa-
ge.. It. is. possible. to. make. corrections. to.
the.values.read.by.the.drill.acting.on.the.
PAR 11.
x 2
ES
PT
ENG
CN10
Fig..9
73