Stroke Setting & Adjustment (Fig 3) - Stanley PB2500N NeoBolt Manual De Instrucciones Y Servicio

Ocultar thumbs Ver también para PB2500N NeoBolt:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

E N G L I S H
Note: DO NOT use spanners to mount Collet (A) onto Front Clutch (Q). Manual tightening of Collet (A) is enough to
lock onto Front Clutch (Q)
3.3 STROKE SETTING & ADJUSTMENT (FIG 3)
3.3.1 INITIAL STROKE SETTING
Determine Application pin stick out length in millimeters ("L" in fi gure below).
Remove battery pack from tool.
Remove Nose Housing (C) and Collet (A) to expose the Stroke Adjustment Pin (N).
Set the Stroke Adjustment Pin (N) to fl ush with Pulling Head Adapter (P).
Rotate the Stroke Adjustment Pin (N) clockwise (CW) according to the following:
Mount the Nose Housing (C) and Collet (A) and tighten the Nose Housing Nut (D).
Verify setting by installing NeoBolt® in Application Grip.
Length (L)
15mm
16mm
17mm
18mm
19mm
20mm
21mm
22mm
23mm
3.3.2 STROKE ADJUSTMENT (FIG 3 & 4)
Remove battery pack from tool.
Insert 2.0mm Hex Key (BB) into front of the tool through the hole in the Collet Stop (Z).
Adjust the tool stroke by rotating the Stroke Adjustment Pin (N) to achieve the desired NeoBolt®
installation. (Ref. Fig. 4)
Each rotation of the Stroke Adjustment Pin (N) changes tool stroke by 1mm (0.04")
To increase the stroke, rotate Stroke Adjustment Pin (N) counter-clockwise (CCW).
To Reduce the stroke, rotate Stroke Adjustment Pin (N) clockwise (CW).
Verify setting by installing NeoBolt® in Application Grip.
Repeat adjustment as needed.
12
Note: Stroke Adj.
pin set fl ush to
pulling head
Pin Adjustment (Number of Rotations)
10 full rotations (CW)
9 full rotations (CW)
8 full rotations (CW)
7 full rotations (CW)
6 full rotations (CW)
5 full rotations (CW)
4 full rotations (CW)
3 full rotations (CW)
2 full rotations (CW)

Publicidad

Tabla de contenido
loading

Tabla de contenido