7. TROUBLESHOOTING GUIDE

Symptom
Tool does not operate when switch
is pressed.
 
 
 
Tool does not return to initial
position when switch is released.
Tool stops before Neobolt is fully
swaged.
 
 
Tool does not return fully
Collet will not release pin
 
 
Tool does not release collar from
anvil
Cause
Battery is defective
Battery is not fully charged
Battery is not fully seated
Battery pack has reached
operating temperature limit
through continuous use or defect.
Electrical malfunction.
Stuck Spindle Clutch.
Battery pack has reached
operating temperature limit
through continuous use or defect.
Improper nosepiece selection.
Setting load of rivet is beyond tool
capacity.
Buildup of debris inside the Nose
Equipment.
Buildup of debris instide nose
equipment
Collet not installed correctly
Anvil is loose
Dirty or worn anvil
Remedy
Replace battery
Charge battery
Remove battery and re-insert.
Reset tool to home.
Remove battery & allow to cool.
Mount battery and reset tool to
home.
Remove battery, wait 5 seconds
and reinsert. Reset tool to home.
Clean Spindle clutch and Spindle
to operate smoothly.
Remove battery & allow to cool.
Mount battery and reset tool to
home.
Reset tool to home, swage Neobolt
collar again.
Reset tool to home, adjust stroke
of tool to proper depth.
Service and clean Nose Assembly.
Service and clean Nose Housing
equipment.
Remove Nose Housing and adjust
collet.
Tighten Anvil
Inspect anvil; clean or replace
E N G L I S H