Cleaning And Maintenance - Vornado EVAP3-EU Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 51
How To Use
Operation
1. Position the unit to not blow directly on objects or plants. Plug the
unit into a 220-240 volt AC outlet.
2. To turn unit On, press the Power button. The indicator lights will
turn on in the default setting HIGH Fan speed and Continuous
Humidity (initial plug-in only).
3. Adjust settings for desired operation. The humidifier will store
your settings during normal On/Off cycles. If the unit becomes
unplugged, it will default to the factory setting - High Fan speed
and Continuous Humidity.
Refilling Water Tank
1. Empty Water Tank before refilling with clean water. Rinse, wipe
clean and dry with clean cloth or paper towel.
2. Refill Water Tank with cool, clean tap water. Do not overfill.
3. Lower humidity control settings or turn Off Humidifier if moisture
forms on walls or windows.
12 English
All manuals and user guides at all-guides.com

Cleaning and Maintenance

Proper cleaning of your Evaporative Vortex Humidifier is essential
to the air quality and performance of your unit. The frequency in
which your Humidifier will need to be cleaned will vary, depending
on use, water hardness, and outside environmental factors. It is
recommended, assuming average use, to thoroughly clean the unit
several times throughout the season, or when algae, mineral deposits
or other particles begin to form.
1. Turn the Humidifier Off and unplug. Do not submerge in water.
2. Remove Power Head and Filters.
3. Remove Water Tank and Inlet Grill. To remove Inlet Grill, undo the
latch (E) and lift Inlet Grill up (F).
F
E
4. Empty the Base and Water Tank, then rinse with clean tap water.
As noted, depending on the quality of water in your home,
impurities can build up quickly or may take some time. It is possible
that some scale may form on the inside of the Base.
To Clean Base
1. Mix a solution of 250 ml. of undiluted white vinegar and 3.8 liters
of water. Fill the Base with the solution; discard any remaining
solution. Let solution stay for 20 minutes.
250 ml
+
3.8 liter
White Vinegar
Water
2. Empty after 20 minutes and clean all interior surfaces with soft
brush. Dampen a soft cloth with undiluted white vinegar and wipe
out Base to remove scale.
3. Rinse thoroughly with clean warm water to remove scale and
cleaning solution before disinfecting the Base.
Disinfecting The Base
1. Mix a solution of 1 teaspoon chlorine bleach and 3.8 liters of water.
Fill the Base with the solution, discard any remaining solution. Let
solution stay 20 minutes. Wet all surfaces.
+
1 tsp.
3.8 liter
Chlorine Bleach
Water
Cleaning and Maintenance
2. Empty Base after 20 minutes. Rinse with water until bleach smell is
gone. Dry with clean cloth or paper towel.
3. We recommend replacing the Filter after use, but to prolong
the life of the Filter, disinfect by washing it in a solution of
one teaspoon of chlorine bleach in one gallon of water. Rinse
thoroughly to get rid of the bleach odor.
4. Reinstall all components. Components must be securely in place
for unit to function properly.
End Of Season Maintenance
1. Follow instructions at end of humidification season or when
Humidifier will not be used for at least one week or more.
2. Let Humidifier dry completely before storing. Do not store with
water inside Water Tank or Base.
3. Remove and discard the Filters if it is not suitable for reuse. Do
not store the Humidifier with wet Filters. If Filters are suitable for
future use, remove and empty water from the Base and Water Tank.
Replace the Water Tank, power unit On and select the HIGH Fan
Speed. Allow the unit to run until the Filters are completely dry.
4. Store in cool, dry location.
English
13

Publicidad

Tabla de contenido
loading

Tabla de contenido