GYS POT COMBI ARCPULL Manual De Instrucciones página 25

Ocultar thumbs Ver también para POT COMBI ARCPULL:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 54
Operating manual
SETUP - OPERATING THE DEVICE
EQUIPMENT DESCRIPTION (FIG-1)
A new-generation, 2-in-1 dent puller. The GYSPOT COMBI ARCPULL is used to remove dents from steel
and aluminium bodywork. Cost-effective and time-saving thanks to its repair technique of pulling out dents without
dismantling the workpice.
This device comprises of two dent pullers with two control panels:
A steel dent puller
With a power source, a hand gun and an earthing cable:
- The trigger gun connects to connector n°6 and its control
cable to connector n°5.
- The triggerless gun
(optional extra)
n°7.
- The earth cable is fixed in position n°4
GYSPOT COMBI ARCPULL machine (FIG-I)
1- Aluminium keypad
2- ON/OFF swtich
3- Keypad (steel)
4- Earth cable (steel)
5- Gun trigger-control connection (steel)
6- Dinse for trigger gun (steel)
-
7
Dinse for triggerless gun (steel)
GYSPOT ARCPULL automatic gun - For aluminium (FIG-I)
1- Trigger
2- Locking ring for electrode holder
3- Rod-locking turn dial
4- Gun control-cable connection
5- Positive dinse
ALUMINIUM HUMAN MACHINE INTERFACE (HMI) (FIG-II)
1- Menu/Enter button
2- Return button
3- G+ button
4- G- button
STEEL HUMAN MACHINE INTERFACE (HMI) (FIG-II)
1- Tool display
2- Power-level display
3- Weld-time display
4- Manual ignition indicator light
5- Auto-ignition indicator light
6- Ignition-type selection button
7- Thermal-fault indicator light
POWER SUPPLY AND STARTING-UP
• This equipment is supplied with a 16 A, CEE7/7 plug and must be connected to a single-phase, 230 V (50 - 60 Hz),
three-wire electrical system with the neutral connected to earth. Check that the power supply and its safeguards (fuse
and/or circuit breaker) are compatible with the current required for use. This device is designed to operate on an elec-
trical system equipped with a 16 A / C, D or K curve circuit breaker.
The effective absorbed current (I1eff) for aluminium and the permanently absorbed current (I1p or ILp) for steel is
indicated on the device for the maximum conditions of use.
Translation of the original
instructions
connects to connector
8- Dinse for gun cables (aluminium) (-)
9- Dinse for gun cables (aluminium) (+)
10- Baseplate for gun control-cable connection (aluminium)
11- Gas outlet for gun cables (aluminium)
12- Mains cable
13- Gas inlet connected to the cylinder (15 l/min) (G1/4 D6)
14- USB connection for software updates (aluminium)
8- Operating-mode selection button (MANUAL/SYNERGY mode)
9- Weld-time selection buttons (+/-)
10- MANUAL mode indicator light
11- Power-level selection buttons (+/-)
12- SYNERGY mode indicator light
13- Tool selection buttons (+/-)
An aluminium dent puller
FOR arc welding with its linear motor gun equipped with
built-in quick earth technology (two flexible studs).
- The gun connects to connector n°8 and n°9.
- The gun control cable connects to connector n°10.
- The gas-supply hose connects to n°13.
6- Negative dinse
7- Gas connection
8- On LED (green)
9- Contact LED (blue)
10- Fault LED (red)
5- D+ button
6- D- button
7- Display screen
GYSPOT COMBI ARCPULL
25

Publicidad

Tabla de contenido
loading

Tabla de contenido