GYS POT COMBI ARCPULL Manual De Instrucciones página 29

Ocultar thumbs Ver también para POT COMBI ARCPULL:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 54
Operating manual
To increase or decrease the arc time (value
To increase or decrease the arc current (value
To change the other manual welding settings (current and welding stage timings) please refer to the chapter 'Manual
Settings'.
MAIN MENU
To access the main menu from both SYNERGY and MANUAL mode, press the Menu/Enter button
Menu Principal
> Réglages
Mode Manuel
Configuration
Press the return button
SYNERGY MODE SETTINGS
Réglages Synergie
> Matériau
> Fe
Gaz
ON
Electrode
anneau
EP. élec.
1.5 mm
different arc values (ignition
the welding process (see
Press the D+ and D- keys to
arc height).
Pressing the Menu/Enter
screen.
Press the return button
Setting range in MANUAL mode
Ignition
-10 to 10 (default value 0)
Holding the
10 - 60 A
electrode
0 - 200 ms
Arc
0 - 200 A
0 - 500 ms
Start up
-10 to 10 (default value 0)
0 - 50 ms
Height
0.5 - 5 mm
Translation of the original
instructions
t
I
ms
), press the G+ and G- keys.
100
100
t
I
ms
A
), press keys D+ and D-.
100
100
zone de
message
zone de
message
Press the G+ and G- keys to move the cursor. Select the item by pressing the Menu/Enter
button
.
• 'Settings' will access the welding settings (synergic or manual).
• MANUAL mode' / 'SYNERGY mode' will change the device's welding mode (SYNERGY
mode <->MANUAL mode).
• 'Configuration' provides access to the appliance's advanced settings (languages, gas ma-
nagement and data, etc.).
to return to the welding screen.
Press the G+ and G- keys to move the left cursor (materials, gas, attachment type and
size). Press the D+ and D- keys to change the values of each item.
Pressing the Menu/Enter
the machine to the synergy welding screen.
Press the return button
MANUAL MODE SETTINGS
Réglages Manuel
Amorce
> Q = 0
button will confirm the manual settings and return the machine to the manual welding
to discard the settings and return to the main menu.
Comments
The default value ensures the best possible ignition without the
risk of breaking the arc when the attachment is lifted whilst also
limiting the short-circuit current.
Increase the ignition slightly if the arc repeatedly breaks.
The default value ensures the best possible attachment of the elec-
trode to the support plate.
A
button will confirm the SYNERGY mode settings and return
to discard the settings and return to the main menu.
Press the G+ and G- keys to successively scroll through the
and fastening coefficients, timings, currents and arc height) of
the 'Drawn-Arc Welding' chapter).
modify the indicated values (coefficients, timings, current and