Note: OVER @ PRG page is available only if OVER P/m is not set to OFF.
Setting Local Action on Overflow Active
• Press the
button to access the Controller's Settings.
• Press the
or
buttons to select OVER-ACTN
• Press the
or
button to select one of the following Actions:
NONE ➞ No action
START ➞ Start the Program(s) selected in the OVER @ PRG page
STOP ➞ Stop the Program(s) selected in the OVER @ PRG page
SKIP ➞ Skip to the next programmed station for the Program(s) selected in the
OVER @ PRG page.
Note: OVER-ACTN page is available only if OVER P/m is not set to OFF.
Setting the Meter Underflow Function.
Meter Underflow status is Normal if during Underflow calculation the number of
pulses per minute from the Water Meter is above the set Pulses/minute Threshold.
Meter Underflow status is Active if during Underflow calculation the number of
pulses per minute from the Water Meter is below the set Pulses/minute Threshold.
Setting Underflow Threshold
• Press the
button to access the Controller's Settings.
• Press the
or
buttons to select UNDR P/m
• Press the
or
button to disable the Underflow function or to select the
Underflow threshold:
Off ➞ 001 . . ➞ . . 200 P/m (pulses per minute).
Note: selecting OFF the following 3 settings are not visualized.
Meter Underflow Delay to Underflow Active.
• Press the
button to access the Controller's Settings.
• Press the
or
buttons to select UNDR-DELAY.
• Press the
or
button to disable Underflow delay or to set a delay time:
Off ➞ 1s . . ➞ . . 8m, increment in seconds.
Note: UNDR-DELAY page is available only if UNDR P/m is not set to OFF.
Setting the Program(s) on Underflow Active.
• Press the
button to access the Controller's Settings.
• Press the
or
buttons to select UNDR @ PRG.
• Press the
or
button to select ALL 4 Programs (A, B, C, D) or ONLY one of
them:
Program A, or
Program B, or
Program C, or
Program D, or
ALL.
Note: UNDR @ PRG page is available only if UNDR P/m is not set to OFF.
Setting Local Action On Underflow Active.
• Press the
button to access the Controller's Settings.
• Press the
or
buttons to select UNDR-ACTN.
• Press the
or
button to select one of the following Actions:
NONE ➞ No action
START ➞ Start the Program(s) selected in the UNDR @ PRG page
STOP ➞ Stop the Program(s) selected in the UNDR @ PRG page
SKIP ➞ Skip to the next programmed station for the Program(s) selected in the
UNDR @ PRG page.
LIFE Plus Controller 4-8-12-16
23