en (original)
An external emergency stop circuit is recommended.
Before running the tool
Before starting the tool, check that the tool is mounted properly and ensure that the motor drive is installed
properly.
Motor drive overview
Motor drive PCB connectors, buttons, jumpers, indicators, mounting holes and dimensions
J4
Dimensions specified in
millimeters.
The motor drive PCB comes mounted in a DIN-rail holder that can be attached to a standard 35 x 7.5mm EN50022 DIN-rail,
but the motor drive PCB can be removed from this holder and mounted using the mounting holes instead. If the mounting
holes are used, then it is recommended to use 20 mm metal standoffs and 10 mm M3 screws when mounting the motor
drive PCB.
It is recommended to use 10 mm ferrules with plastic sleeve for each wire that is attached to any of the connectors. The
wires can then easily be pushed into the connectors and released with the help of a small flat-head screwdriver (3.5 mm
blade width, 0.6 mm blade thickness).
Connector description
Connector
J1
J1
J1
J1
Connector
J2
J2
Connector
J3
J3
J3
J6
D26
D25
D24
D23
D22
J1
D21
D20
D19
D18
D17
D3
D2
GND
A
B
GND
ø 3,20
PIN
GND
A
B
GND
PIN
GND
48V
PIN
P+
C+
C-
200
J5
J2
S1
GND
48V
S2
155
Description
GND
Modbus RTU RS-485 (A)
Modbus RTU RS-485 (B)
GND
Description
GND
48 VDC input
Description
P+
C+
C-
NTC-
GND
PhaseC
PhaseB
PhaseA
NTC+
P-
C-
C+
P+
D36
15
Mirka® Motor Drive Cabinet
21