Profinet I/O to Modbus RTU signal mapping
Name
SetRelay
SetSpeedRegister
SetOperationRegister
DeviceName
CommonInputs
MiscInputs
AlarmStatus
FirmwareVersion
PartVersionSerialNumber
GetSpeedRegister
GetOperationRegister
ReadCoils
Siemens TIA Portal V14 gateway mapping example
Below is a screenshot from TIA Portal V14 showing how the gateway can be mapped into the system. Use the GSDML file
that is downloadable from the Hilscher website to add support for the Hilscher NT 50-RS-EN gateway into your system.
Basic operation for Modbus RTU
The motor drive must be in ON-state before the tool can be started. The very first command that should be sent to the
motor drive is the ON-state command. It is not mandatory to send the OFF-state command before removing power from
the motor drive.
When the motor drive is in ON-state the speed set-point value can be written and the state can be set to RUN-state by
sending the RUN-state command. This will cause the tool to run at the set-point speed. To stop the tool, set the motor
drive to STOP-state by sending the STOP-state command.
It is recommended to continuously monitor the average speed, average current, tool temperature, motor drive temperature
and the alarm status flag. This will help to detect if there are any issues present during operation.
Example sequence for starting and stopping the tool:
• Write 4 (0x0004) to the "Operation" register, this will set the motor drive to ON-state.
28
Mirka® Motor Drive Cabinet
Modbus re-
Data length
gister
00012
1 coil
40011
1 register
40012
1 register
40001-40010
10 registers
30017-30020
4 registers
30001–30016
16 registers
30047
1 register
30021–30030
10 registers
30031–30046
16 registers
40011
1 register
40012
1 register
00001–00012
12 coils
Trigger
Profinet I/O
Changed data
1
Changed data
2
Changed data
3
Cyclically 10
4
sec.
Cyclically 1 sec.
5
Cyclically 5 sec.
6
Cyclically 1 sec.
7
Cyclically 10
8
sec.
Cyclically 10
9
sec.
Cyclically 1 sec.
10
Cyclically 1 sec.
11
Cyclically 1 sec.
12
Data length
1 byte out
1 word out
1 word out
10 words in
4 words in
16 words in
1 word in
10 words in
16 words in
1 word in
1 word in
2 bytes in