exceed 2.8 meter.
When
the
vertical
extension
8086950 is used, the terminal part of the
pipe must always come out horizontally.
2.6.2
Positioning the
outlet terminals
The outlet terminals for forced-draught
appliances may be located in the external
perimeter walls of the building.
To provide some indications of possible solu-
tions, Table 1 gives the minimum distances
to be observed, with reference to the type
of building shown in fig. 7.
2.6.3
Coaxial duct outlet
on the roof
The roof discharge terminal L. 1285 cannot
be shortened and when positioning the tile,
the minimum distance from the discharge
head terminal must not be less than 600
mm (fig. 8).
The accessories to be used for this type of
installation and some of the connecting
systems that may be adopted are illustra-
ted in fig. 9.
It is possible to insert up to a maximum of
three extensions and reach a maximum
rectilinear distance of 3.7 meter.
Should it be necessary to make two chan-
ges of direction in the pipe development,
the maximum length of the pipe must not
exceed 2 meter.
KEY
1 Tile with articulated joint
2 Lead panel
3 Collar
4 Locking screw
code
TABLE 1
Siting of terminal
A - below openable window
B - below ventilation opening
C - below eaves
D - below balcony (1)
E - from adjacent window
F - from adjacent ventilation opening
G - from horizontal or vertical soil or drain pipes (2)
H - from corner of building
I - from recess in building
L - from ground level or other treadable surface
M - between two terminals set vertically
N - between two terminals set horizontally
O - from a surface facing without openings or terminals
P - as above but with openings and terminals
1) Terminals below a practicable balcony must be located in such a way that the total path of the smoke
from its outlet point from the terminal to its outlet point from the external perimeter of the balcony, inclu-
ding the height of possible railings, is not less than 2000 mm.
2) When siting terminals, where materials that may be subject to the action of the combustion products
are present in the vicinity, e.g., eaves, gutters and downspouts painted or made of plastic material,
projecting timberwork, etc., distances of not less than 1500 mm must be adopted, unless adequate
shielding is provided to guard these materials.
Fig. 8
Appliances from 7 to 35 kW
NOTE
Before connecting accessories, it is
always advisable to lubricate the
internal part of the gaskets with sili-
con products. Avoid using oils and
greases.
KEY
1 Vertical extension L. 140 with take-off
points code 8086950
2a Extension L. 1000 code 8096150
2b Extension L. 500 code 8096151
3 Tile with articulation joint code 8091300
4 Roof outlet terminal L. 1285 code 8091205
5 Supplementary 90° elbow code 8095850
6 Supplementary 45° elbow code 8095950
IT
ES
PT
GB
Fig. 7
(distances in mm)
600
600
300
300
400
600
300
300
300
2500
1500
1000
2000
3000