from low-voltage wires, or they must be suitably insulated with at least 1mm of
additional insulation. Wires must be secured with additional fastening near the
terminals, using devices such as cable clamps.
13.1) FACTORY CONNECTIONS (Fig. P Rif. 1)
TERMINAL
DESCRIPTION
Power supply unit wiring
JP2-JP4
JP2= brown
JP4= white/blue
Gearbox wiring
JP7-JP8
JP7=brown
JP8=white/blue
JP12
Encoder wiring
JP19
Solenoid lock wiring
13.2) USER CONNECTIONS (Fig. N-P)
IMPORTANT NOTE: USE ONLY SHIELDED CABLES WITH EARTHED BRAI-
DING
TERMINAL
DESCRIPTION
L
PHASE
N
NEUTRAL
EARTH
JP18
Universal palmtop programmer connector
JP10
Connector for additional optional boards
1
Controllers common
2
OPENING SAFE 1 (NC)
3
CLOSING SAFE 2 (NC)
4
STOP (NC) input
5
EXT. RADAR control (NO) input
6
INT. RADAR control (NO) input
7
OPEN KEY (NO) input
MULTIFUNCTION Input
8
(par. MULTIFUNCTION INPUT OPERATING MODE)
9
Control common
10
OPENING SAFE 3 (NC)
11
CLOSING SAFE 4 (NC)
12-13
Test output for tested safety devices
Serial RS485.
14 = A
15 = B
14-15
Connection to external programming devices.
Controllers common
Connection of remote door in cage mode
16-17
Accessories power supply
"Alarm" output
18 = NO (voltage-free contact)
18-19-20
19 = COM (voltage-free contact)
20 = NC (voltage-free contact)
"Door status" output
21 = NO (voltage-free contact)
21-22-23
22 = COM (voltage-free contact)
23 = NC (voltage-free contact)
14) CENTRAL PROGRAMMING (Fig.C1)
14.1) PARAMETER MENU (PARA )
(TABLE "A" PARAMETERS)
14.2) LOGIC MENU (logic)
(TABLE "B" LOGIC)
14.3) RADIO MENU (RADIO)
Logic
Description
Add Start Open
add open
associates the desired key with the Open command
INSTALLATION MANUAL
add
ey
erase 64
cod RX
u
-
IMPORTANT NOTE: THE FIRST TRANSMITTER MEMORIZED MUST BE
IDENTIFIED BY ATTACHING THE KEY LABEL (MASTER).
In the event of manual programming, the fi rst transmitter assigns the RECEIVER'S
KEY CODE: this code is required to subsequently clone the radio transmitters.
The Clonix built-in on-board receiver also has a number of important advanced
features:
Cloning of master transmitter (rolling code or fi xed code)
Cloning to replace transmitters already entered in receiver
Transmitter database management
Receiver community management
To use these advanced features, refer to the universal handheld programmer's
instructions and to the general receiver programming guide.
14.4) DEFAULT MENU (default)
Restores the controller's default factory settings.
14.5) LANGUAGE MENU (language)
Used to set the programmer's language on the display.
14.6) AUTOSET MENU (Autoset) (Fig. R )
When this function is activated, the parameters relating to door movement and
obstacle detection are automatically set to their optimum values:
- Running speed during opening
- Running speed during closing
- Opening slow-down distance
- Closing slow-down distance
- Opening deceleration distance
- Closing deceleration distance
- Acceleration
- Deceleration
- Opening force
- Closing force
3 complete cycles are performed as the autoset function is run.
While autoset is running, the anti-crush function is not active.
The door must not be stopped or slowed down at any point during its
travel while autoset is running.
14.7) STATISTICS MENU
Used to view the version of the board, the total number of operations (in
hundreds), the number of transmitters memorized and the last 30 errors (the
fi rst 2 digits indicate the position, the last 2 give the error code). Error 01 is the
most recent.
14.8) PASSWORD MENU
Used to set a password for the board's wireless programming.
15) CENTRAL OPERATION:
15.1) DOOR OPERATION MODE
Mode 0) Standard operation door (Fig. Q)
Reaction to commands:
- Open key:
Opens at high speed, closes at low speed. Opens and activates an Open-key
operation, if activated while the door is open, it sets clear time to zero; reopens
if activated during closing. With the door open, the clear-time countdown is
active. During closing, photocells stop movement instead of reversing. Once
they are cleared, closing is resumed following the TCA countdown. During the
Open-key operation, the radars are not active.
- External radar:
Performs a high-speed cycle. Opens, with the door open, it triggers the auto-
matic closing time; if activated while the door is open, it sets automatic closing
time to zero. Following the automatic closing time, the door closes. During
closing, it causes the door to open again.
During closing, it carries out a reopening manoeuvre.
- Internal radar:
Performs a high-speed cycle. Opens, with the door open, it triggers the automatic
closing time; if activated while the door is open, it sets automatic closing time
to zero. Following the automatic closing time, the door closes. During closing,
it causes the door to open again.
- Safety device during opening:
During opening, it stops movement until the photocell is cleared. With the
door open, it sets the TCA or clear time to zero. If triggered, it prevents the
door from starting to open and close.
- "Presence sensor" safety device:
During opening, movement takes place at slow speed; during other stages,
Add Open Key
associates the desired key with the Open Key command
Erase List
WARNING! Erases all memorized remote controls from
the receiver's memory.
Read receiver code
Displays receiver code required for cloning remote controls.
ON = Enables remote programming of cards via a previously me-
morized W LINK transmitter. It remains enabled for 3 minutes
from the time the W LINK remote control is last pressed.
OFF= W LINK programming disabled.