DSC PowerSeries neo HS2LEDX Instrucciones De Instalación página 7

Ocultar thumbs Ver también para PowerSeries neo HS2LEDX:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Table 8: Wireless Supervisory Window Options
00
Enabled/Disabled
01
After 1 Hour
02
After 2 Hour
03
After 4 Hour
04
After 8 Hour
05
After 12 Hour
06
After 24 Hour
3. Press [*] to accept the selection.
4. Press [#] to exit the section.
NOTE: For UL Residential Burglary (UL1023), Home Health Care (UL1637), ULC Residential Burg-
lary (ULC/ORD-C1023) installations, the maximum Supervision window shall be set to 24 hours.
For UL Residential Fire (UL985) installations, the maximum supervision window is set to 200s.
For UL Commercial Burglary (UL1610/UL365) and ULC Residential Fire (ULC-S545), the maximum
supervision window shall be set to 4 hours.
[804][810] Wireless Option 1
To program wireless options:
1. Enter Installer Programming section [804][810].
2. Select one of the following options by scrolling or entering the hotkey.
Table 9: Wireless Options
On: the system cannot be armed if a wireless supervisory trouble exists. An RF
RF Delin-
01
delinquency trouble is generated.
quency
Off: wireless supervisory troubles do not prevent arming.
Wireless
On: if a supervisory or jamming trouble occurs during Away arming, the siren
Supervisory/
activates and the event is logged and reported.
02
RF Jam
Off: supervisory or RF jam troubles during Away arming do not activate the
Alarm
siren or get logged and reported.
Module
On: module tampers are logged and reported.
03
Tamper
Off: module tampers are not logged or reported.
On: fire devices are supervised every 200 seconds. If the device fails to report
within this window, a supervision trouble is generated.
Fire Super-
04
Off: fire devices follow the supervision window programmed in section 802, up
vision
to a maximum of 18 hours. The supervisory window can be programmed with a
higher value, but detectors still go into fault after 18 hours.
3. Press [*] to accept the selection and [#] to exit.
[804][841] Visual Verification Programming
To program wireless options:
1. Enter Installer Programming section [804][841].
2. Select one of the following options by scrolling or entering the hotkey
Table 10: Visual Verification Sub-Sections
On: Alarms trigger image capture from PIR Cameras
001 Visual Verification
Off: Alarms do not trigger image capture from PIR Cameras
01 Alarm + 5 Minutes
002 View Time Window
02 Alarm + 15 minutes
03 Alarm + 1 Hour
01 Fire key enabled/disabled
02 Duress key enabled/disabled
003 View Other Alarms
03 Medical key enabled/disabled
04 Panic key enabled/disabled
firealarmresources.com
[804][901]-[905] Delete Wireless Devices
To delete wireless devices:
1. Enter Installer Programming section [804] then select one of the following sub-sections:
Table 11: Module Label Sub-Sections
Sub-Section
Description
901
Delete wireless zone devices
902
Delete wireless key
903
Delete sirens
904
Delete repeaters
905
Delete keypads
2. Select a device to delete using the scroll keys or go directly to a specific device by entering a
hotkey.
3. Press [*] to delete or [#] to exit.
[804][921]-[925] Replace Wireless Devices
Use this option to replace a faulty device enrolled on the system with another device of the same type
while maintaining the configuration of the original. The faulty device does not need to be deleted. To
replace a wireless device:
1. Enter Installer Programming section [804] then select one of the following sub-sections.
Table 12: Replace Device Sub-Sections
Sub-Section
Description
921
Replace wireless zone devices
922
Replace wireless keys
923
Replace sirens
924
Replace repeater
925
Replace keypad
2. Press [*] to select a sub-section. The first available device is displayed.
3. Select a device to replace using the scroll keys or go to a specific device by entering a hotkey.
Press [*]. When prompted, activate the device (full enrollment) or enter the device ID (pre-enrollment).
A message is displayed confirming enrollment.
[804][990][001- 005] Show All Devices
Use this section to review wireless devices enrolled on the system and to view serial numbers asso-
ciated with each device.
To review wireless device information:
1. Enter Installer Programming section [804][990] then select one of the following sub-sections:
Table 13: Wireless Device Sub-Sections
Sub-Section
Descriptions
001
All zones
002
Repeaters
003
Sirens
004
Wireless keys
005
Keypads
2. Press [*] to select a wireless device type. The first available device is displayed.
3. Use the scroll keys to view the enrolled devices.
NOTE: This option is not fully supported by LED and ICON keypads.

Publicidad

Tabla de contenido
loading

Tabla de contenido