Fault :
Water collects in the bottom of the cabinet.
Possible cause :
The defrost water pipe is blocked.
Remedy :
Clean the defrost water channel and the drain hole on the
rear wall of the cabinet.
C.
Fault :
Vibration or bothersome noise.
Possible cause :
The appliance is not level.
The appliance is resting against other kitchen elements.
Containers or bottles inside the cabinet are rattling against
one another.
Remedy :
Level the appliance using a spirit level.
Move the appliance away from the kitchen elements or
appliances it is in contact with.
Move containers and/or bottles apart.
D.
Fault :
Compressor runs continuously.
Possible cause :
High room temperature.
Remedy :
Ensure adequate ventilation.
E.
Fault :
P1 is shown on the display.
Possible cause :
The upper sensor is disconnected or short-circuited.
Remedy :
Call for service. The temperature within the entire cabinet is
maintained at the higher of the two setpoints until the fault
has been corrected.
F.
Fault :
P2 is shown on the display.
Possible cause :
The lower sensor is disconnected or short-circuited.
Remedy :
Call for service. The temperature within the entire cabinet is
maintained at the higher of the two setpoints until the fault
has been corrected.
If the fault persists after carrying out the above checks, contact
the After-Sales Service, remembering to specify:
the type of fault;
`
`
the appliance PNC (production number code);
`
`
the Ser. No. (appliance serial number).
`
`
Note: The code and serial number are essential for iden-
tifying the type of appliance and date of manufacture:
WINE CABINET
Model No
xxxxxxxxxxx
PNC
xxxxxx
xxxxxxxx
SN
Year
xxxx
Climate class
xxx
Volt / Hz
220-240V~ / 50 Hz
kW / A
xxxxx
Ph
1~ + N +
Kg / Net. Vol
xxxxxx

Maintenance intervals

The inspection and maintenance intervals depend on the
actual machine operating conditions and ambient condi-
tions (presence of dust, damp, etc.), therefore precise time
intervals cannot be given. In any case, careful and periodical
machine maintenance is advisable in order to minimise ser-
vice interruptions.
It is advisable to stipulate a preventive and scheduled
maintenance contract with the After-Sales Service.

Maintenance frequency

To ensure constant machine efficiency, it is advisable to carry
out the checks with the frequency given in the following table:
Maintenance, inspections, checks and cleaning Frequency
Routine cleaning
general cleaning of machine and surrounding area
Mechanical protection devices
check their condition and for any deformation,
loosening or removed parts
Control
check the mechanical part, for cracks or
deformation, tightening of screws: check the
readability and condition of words, stickers and
symbols and restore if necessary
Machine structure
tightening of main bolts (screws, fixing systems,
etc.) of machine
Safety signs
check the readability and condition of safety signs
Electrical control panel
check the electrical components installed inside
the electrical control panel. Check the wiring
between the electrical panel and machine parts.
Electrical connection cable and plug
check the connection cable (replace if necessary)
and plug
Some examples of checks to be carried out are given below.
check for any oxidised electrical components or parts; if
`
`
necessary, replace them and restore the initial conditions;
check the structure and welded joints in particular;
`
`
check and replace bolts and/or screws, also checking for
`
`
any loose components;
check the electrical and electronic system;
`
`
check the functionality of safety devices;
`
`
check the general condition of protection devices and guards.
`
`
REFRIG. R600a xxxxx KG
Made in Denmark
daily
monthly
yearly
yearly
yearly
yearly
yearly