Maintenance

• Prior to maintenance, disconnect paint spray gun from the com-
pressed air circuit!
• Disassemble and install components very carefully! Exclusively use
included special tools!
9.1. Replacing the Nozzle Set
and [7-6]
Every SATA nozzle set consists of "paint needle" [7-1], "air cap" [7-2]
and "fluid tip" [7-3] and has been hand-adjusted to provide a perfect
spray pattern. Therefore, always exchange the complete nozzle set. After
installation, please adjust material flow according to chapter 7.2.
9.2. Replacing the Air Distribution Ring Steps:
[7-2], [7-3], [8-1], [8-2] [8-3], [7-4], [7-5] and [7-6]
• Remove air distribution ring with SATA extraction tool only.
• Do not apply force to avoid damage of sealing surfaces.