INSTALLATION INSTRUCTIONS
Wall holder model 032.01 - 032.02
032.04 - 032.04/L
Model 032.01
Standard model with on/off switch
Model 032.02
Model with standard European socket 2P + earthing 16A and
hairdryer on/off switch
Model 032.04 - 032.04/L
Model with universal shaver socket and hairdryer on/off switch.
A safety transformer insulates the shaver socket from the mains
and a protection device inhibits the operation of appliances with a
load higher than 20VA.
Installation of wall holder
This work should only be carried out by a suitably qualified
electrical engineer, in order to comply with the existing national
safety regulations. When the spiral cord is extended to its
maximum length, the hairdryer shall not be reached by a person
using the bath or the shower.
There are two possible methods of installation:
A = connection to wall mains wiring
B = connection to surface mains wiring
Attention: before installing the hairdryer
always switch off the general switch
of your mains electricity.
For each pole a switch with a minimum break distance between
contacts of 3 mm must be fitted up-line of the appliance.
Each time the appliance is opened, the switch must be used to
disconnect the appliance.
Method A (connection to wall mains wiring)
for wall holder model 032.01 - 032.02
032.04 and 032.04/L
The connection wiring from the mains must be at least
2
3x1,5 mm
for wall holder model 032.02.
The connection wiring from the mains must be at least
2x1,0 mm
2
for wall holder models 032.01, 032.04 and
032.04/L
1. Separate the cover (1) of the wall holder from the back plate
by loosening the screw (14).
2. Remove the knockout (2) provided in the back plate of the
wall holder.
3. Feed the mains supply cable (3) coming out of the wall into
the hole in the back plate left after removing the knockout (2).
4. Secure the back plate of the wall holder to the wall using the
plugs and screws provided.
5. Remove the terminal connector (4), connect the mains
supply cable (3) to the terminal connector (4), as shown
in the picture, and then secure again the terminal
connector (4).
6. Model 032.01, 032.04 and 032.04/L are double insulated
and no earth connection is provided. Model 032.02 (with
standard European socket 2P + earthing): the earth cable
from the wall must be connected to the terminal connector.
The cables shall withstand 16A.
7. Fit the front cover of the wall holder, taking care to locate
the cable sleeve (6) properly.
8. Secure the front cover with the screw (14).
9. Switch on the general switch of your mains electricity. The
hairdryer is ready for use.
Method B: (connection to surface mains
wiring) only for wall holder model
032.01 - 032.04 and 032.04/L
The connection wiring must be at least type H05VV-F 2x1,0 mm
1. Separate the cover (1) of the wall holder from the back plate
by loosening the screw (14).
2. Remove the knockout (8) provided in the base of the back
plate of the wall holder for feeding the cable sleeve (11).
3. Secure the back plate of the wall holder to the wall using the
plugs and screws provided.
4. Feed cable sleeve (11) over end of mains cable (13),
remove the terminal connector (9), connect the mains
supply cable (13) to the terminal connector (9), as shown
in the picture, and then secure again the terminal connector
(9). Secure the cable grip (10) with the screws provided.
5. Locate the cable sleeves (6) and (11) in the slot provided in
the base of the back plate.
6. Fit the front cover of the wall holder, taking care to locate
the cable sleeves (6) and (11) properly.
7. Secure the front cover with the screw (14).
8. Switch on the general switch of your mains electricity. The
hairdryer is ready for use.
INSTRUCTIONS FOR USE
Control Switches
Control switch on wall holder 0-1 = Off/On
Hairdryer Mod. 530.02 - 530.15 - 530.22
533.03 - 533.05 - 540.05 - 540.06 - 542.05
and 542.06
Blue pushbutton:
Slide Switch
Hairdryer
Type 554.02 - 554.05 - 554.08 - 554.11
554.13
Pushbutton:
ON=On/Off (pressure must be maintained to operate the
hairdryer)
Slide Switch
1=(low power)
2=(maximum power)
5
ON = On/Off (pressure must
be maintained to
operate the hairdryer)
Cool = (low power)
1 = (medium power)
2 = (maximum power)
2