Operating Manual SATAjet 4600 B RP/HVLP
nozzle set. After installation, please adjust material flow according to
chapter 7.2.
9.2. Replacing the Air Distribution
2], [7-3], [8-1], [8-2] [8-3], [7-4], [7-5] and [7-6]
• Remove air distribution ring with SATA extraction tool only.
• Do not apply force to avoid damage of sealing surfaces.
Check sealing surfaces inside the spray gun [8-2] after disassembly,
clean them, if required. Should the sealing surfaces be damaged,
please contact your SATA dealer. Align new air distribution ring by
means of the marking [8-3], (pin into drilling) and press in with even
force. Adjust material flow according to chapter 7.2 after installation.
9.3. Replacing the Paint Needle Sealing Steps:
and [9-3]
When paint material leaks from the self-tensioning paint needle packing, it
needs to be replaced. Remove trigger according to [9.2]. After disassembly,
check if the paint needle is damaged or replace the nozzle set, if required.
Adjust material flow according to chapter 7.2 after installation.
9.4. Replacing the Air Piston, Air Piston Spring
and Air Micrometer Steps:
• Disconnect the spray gun from the compressed air circuit!
When air leaks from the air cap or the air micrometer without the trigger
being pulled, they need to be replaced. After disassembly, grease the air
micrometer sleeve with SATA high performance grease (Art. No. 47173),
insert it together with the air piston and tighten the locking screw [10-1].
Adjust material flow according to cahpter 7.2 after installation.
Notice!
Information!
Danger!
Ring Steps: [7-1], [7-
[10-1], [10-2] and [10-3]
US
[9-1], [9-2]
111