Operating Manual SATAjet 4600 B RP/HVLP
plete nozzle set. After installation, please adjust material flow according to
chapter 7.2.
9.2. Replacing the air distribution ring
2], [7-3], [8-1], [8-2] [8-3], [7-4], [7-5] und [7-6]
• Remove the air distribution insert with the SATA extraction tool only.
• Do not apply force to avoid damage of sealing surfaces.
Check sealing surfaces inside the spray gun [8-2] after disassembly,
clean them, if required. Should the sealing surfaces be damaged,
please contact your SATA dealer. Align new air distribution ring with the
help of the marking [8-3], (pin must be located in the drilling) and press
in with even force. Adjust material flow according to chapter 7.2 after
installation.
9.3. Replacing the paint needle sealing
and [9-3]
When paint material leaks from the self-tensioning paint needle packing, it
needs to be replaced. Remove trigger according to [9.2]. After disassem-
bly, check if paint needle is damaged or replace the nozzle set, if required.
Adjust material flow according to chapter 7.2 after installation.
9.4. Replacing the air piston, air piston spring and
air micrometer
• Disconnect the spray gun from the compressed air circuit!
When air leaks from the air cap or the air micrometer without the trigger
being pulled, they need to be replaced. After disassembly, grease the air
micrometer sleeve with SATA high performance grease (Art. No. 47173),
insert it together with the air piston and tighten the locking screw [10-1].
Adjust material flow according to chapter 7.2 after installation.
Attention!
Note!
Steps: [10-1], [10-2] and [10-3]
Warning!
Steps: [7-1], [7-
Steps: [9-1], [9-2]