Product description

Key:
— = Not permitted, • = Permitted
3.2

Improper use

DANGER
Explosion due to pumping of explosive fluids!
Pumping of highly flammable and explosive fluids (gasoline, kerosene, etc.) in pure
form is strictly prohibited. There is a risk of fatal injury due to explosion! The
pumps are not designed for these fluids.
The submersible pumps must not be used for pumping of:
▪ Untreated sewage
▪ Sewage containing faeces (as per EN 12050-1)
▪ Drinking water
▪ Fluids containing hard components (such as stones, wood, metal, etc.)
▪ Fluids containing high quantities of abrasive contents (e.g. sand, gravel).
Intended use requires compliance with this manual. Any other use is regarded as non-
compliant with the intended use.
4
Product description
4.1

Design

Fig. 1: Overview
1
Installation and operating instructions Wilo-Drain TM/TMW 32 60Hz
6
5
4
Handle
1
2
3
en