2. Stop the engine (generator). See the "Stopping the
Engine (Generator)" section for stopping procedure.
3a. Gasoline to Propane/LPG
• Fully open the Propane/LPG cylinder knob.
• Turn the fuel source switch to the propane/LPG
position.
3b. Propane/LPG to Gasoline
• Make certain the propane tank is fully closed.
• Turn the fuel source switch to the gasoline
position.
4. Start the engine (generator). See the "Starting the
Engine (Generator)" section for starting procedure.
Parallel Operation (2 x SUA2000iD Models)
WARNING
Fire and electrocution hazard. Never connect or
disconnect the parallel cord leads when a generator
is running. Do not parallel more than two generators.
Use only AIPOWER generators for paralleling.
NOTICE
Paralleling this generator to a generator that is not
compatible can cause a low voltage output that can
damage tools and appliances powered by the
generator. Do not connect or disconnect parallel
cables while the generator is running to avoid damage.
Parallel operation gives you the ability to link this
generator to a compatible AIPOWER generator for
combined running and starting power output. Use
only the AIPOWER approved cables for parallel
operation. For single generator operation, the parallel
operation cable must be removed.
NOTE:
Only connect two identical (same model) generators
together for parallel operation.
Page 20