Checking For Leaks - Whirlpool W11581317 Hoja De Instrucciones

L.p. kit de conversion a gas propano y butano, conversion de quemadores de gas de 20.000 btu/h de gas natural a petroleo licuado gas embotellado
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire, or electrical shock.
5.
Plug in dryer or reconnect power.
6.
Turn on gas supply.
7.
Set dryer cycle to time dry, high heat and turn on dryer.
8.
After ignition, verify gas inlet pressure is between 8" (203
mm) and 13" (330 mm) water column.
9.
Turn off dryer.
10. Unplug dryer or disconnect power.
11. Turn off gas supply.
12. Disassemble control panel or top and console assembly
(depending on application) and front panel assembly from
dryer to regain access to burner assembly.
13. Disconnect manometer and remove hose from pressure tap.
14. Remove pressure tap.
15. Reinstall pressure tap plug to gas valve and tighten.
NOTE: Pressure tap plug can be reinstalled and securely tighten to
gas valve body without removal of the bulkhead assembly with
the use of a 3/16" hex wrench.

Checking for Leaks

1.
With front panel removed, brush or spray an approved non-
corrosive leak detection solution onto pressure tap plug.
2.
Reassemble dryer in reverse order as described in
"Disassembling the
Dryer."
3.
Turn on gas supply.
4.
Plug in dryer or reconnect power.
5.
Set dryer cycle to time dry, high heat and turn on dryer.
6.
View through the hole on the right side panel inspecting for
leaks indicated by growing bubbles. See below figure.
A.
Pressure Tap Plug
B.
Side View Hole
C.
Gas Valve Body
7.
If any bubbles are present, turn off gas supply, tighten the
leaking connection and retest for leaks.
8.
If dryer was moved during conversion, use the same method
to check for leaks in the flexible gas supply line and fittings
between the dryer and the gas supply pipe.
9.
If any bubbles are present, tighten the leaking connection
and retest for leaks.
NOTE: Replace flexible gas supply line if bubbles are present on
supply line.
10. If no bubbles are present, reinstall hole plug to side panel
and unplug dryer.
Completing the Conversion
1.
Check to assure all components are attached securely in
place and lint filter has been installed to dryer.
2.
Reattach dryer top or top and console assembly (depending
on application). If dryer was moved from its original position,
reposition dryer to its location.
3.
Connect external exhaust vent to dryer.
4.
Plug in dryer or reconnect power.
5.
Check that dryer is working properly by:
• Turning on dryer.
• Running on high heat for 5 minutes.
• Checking for heat in drum.
14