SUITABLE PERSONNEL

Suitable Personnel
E N
NOTE:
The product may only be used by trained
specialised personnel.

Warranty/Exclusion of Liability

Application-technical recommendations,
whether given orally, in writing or in the course
of practical training, are guidelines. Our prod-
ucts are subject to continuous further develop-
ment and are tested according to the state of
the art and to legal requirements. We reserve
the right to make any resulting changes in han-
dling and composition.
The respectively valid instruction-manual ver-
sion can be found under
www.amanngirrbach.com/instruction-manuals.
This version replaces all previous versions.

Product Specifications

Intended use
The purpose of the Clinometer System is to
adapt indirect dentures in the anterior region to
the facial characteristics of the patient. It can
also be used for planning and monitoring ortho-
dontic treatment and oral surgery.
Product Description
The Clinometer System according to Dr.
Behrend is used for determining and transferring
esthetic parameters to the patient. It consists of
the following two components: The operatory
clinometer and the laboratory clinometer. At the
dentist's, the operatory clinometer is attached
14
to the Artex facebow. The Clinometer shield is
not in contact with the patient. In the dental lab,
the laboratory clinometer is attached to the
articulator and the determined data is trans-
ferred to the prosthetic restoration.
The Clinometer System ensures that every pros-
thetic restoration in the anterior region is
adapted to the facial characteristics, such as:
_ veneers
_ crowns
_ fixed and removable partial dentures
_ full dentures
_ implant-supported dentures
However, it can also be used for planning and
monitoring orthodontic treatment and oral sur-
gery.
Using the operatory clinometer, the dentist
determines the ideal angle of the teeth as
viewed from the front. This angle - the esthetic
angle - is noted down and sent to the laboratory
together with the order form. The dental techni-
cian mounts the laboratory clinometer to the
articulator and uses the vertical auxiliary lines of
the "programmed " laboratory clinometer for ori-
entation, when setting up the tooth front.
Even if a dental technician receives only a wax
rim or a model of the temporary restoration as a
guide for the tooth alignment, the use of the lab-
oratory clinometer is still very helpful. By insert-
ing the wax rim or model of the temporary
restoration in the articulator, the correct teeth
angles and incisal edges can be determined with
the laboratory clinometer. This numerical infor-
mation can be retrieved at any time using the
laboratory clinometer.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

219950219950c

Tabla de contenido